The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Temperature Dependence of Ion and Water Transport in Perfluorinated Ionomer Membranes for Fuel Cells
Abstract
To clarify the mechanisms of transport of ions and water molecules in perfluorosulfonated ionomer membranes for fuel cells, the temperature dependence of their transport behaviors was investigated in detail. Two types of Flemion membranes having different equivalent weight values (EW) were utilized along with Nafion 117 as the perfluorinated ionomer membranes, and H-, Li-, and Na-form samples were prepared for each membrane by immersion in 0.03 M HCl, LiCl, and NaCl aqueous solutions, respectively. The ionic conductivity, water self-diffusion coefficient (D(H)(2)(O)), and DSC were measured in the fully hydrated state as a function of temperature. The ionic conductivity of the membranes was reflected by the cation transport through the intermediary of water. Clearly, H(+) transports by the Grotthuss (hopping) mechanism, and Li(+) and Na(+) transport by the vehicle mechanism. The differences of the ion transport mechanisms were observed in the activation energies through the Arrhenius plots. The D(H)(2)(O) in the membranes exhibited a tendency similar to the ionic conductivity for the cation species and the EW value. However, no remarkable difference of D(H)(2)(O) between H- and the other cation-form membranes was observed as compared with the ionic conductivity. It indicates that water in each membrane diffuses almost in a similar way; however, H(+) transports by the Grotthuss mechanism so that conductivity of H(+) is much higher than that of the other cations. Moreover, the D(H)(2)(O) and DSC curves showed that a part of water in the membranes freezes around -20 degrees C, but the nonfreezing water remains and diffuses below that temperature. This fact suggests that completely free water (bulk water) does not exist in the membranes, and water weakly interacting with the cation species and the sulfonic acid groups in secondary and higher hydration shells freezes around -20 degrees C, while strongly binding water in primary hydration shells does not freeze. The ratio of freezing and nonfreezing water was estimated from the DSC curves. The D(H)(2)(O) in the membranes was found to be influenced by the ratio of freezing and nonfreezing water. DFT calculation of the interaction (solvation) energy between the cation species and water molecules suggested that the water content and the ratio of freezing and nonfreezing water depend strongly on the cation species penetrated into the membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kreuer, K.-D., Paddison, S. J., Spohr, E., & Schuster, M. (2004) · Chemical Reviews · doi:10.1021/cr020715f · Cited by 2,187
Determination of water diffusion coefficients in perfluorosulfonate ionomeric membranes
Zawodzinski, T. A., Neeman, M., Sillerud, L. O., & Gottesfeld, S. (1991) · The Journal of Physical Chemistry · doi:10.1021/j100168a060 · Cited by 987
Cited by
New Insights into Perfluorinated Sulfonic-Acid Ionomers
Kusoglu, A., & Weber, A. Z. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00159 · Cited by 2,432
Parallel cylindrical water nanochannels in Nafion fuel-cell membranes
Schmidt-Rohr, K., & Chen, Q. (2008) · Nature Materials · doi:10.1038/nmat2074 · Cited by 1,371
Review: Durability and Degradation Issues of PEM Fuel Cell Components
de Bruijn, F. A., Dam, V. A. T., & Janssen, G. J. M. (2008) · Fuel Cells · doi:10.1002/fuce.200700053 · Cited by 1,001
Review of electrochemical ammonia production technologies and materials
Giddey, S., Badwal, S. P. S., & Kulkarni, A. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.09.054 · Cited by 886
A review of the main parameters influencing long-term performance and durability of PEM fuel cells
Schmittinger, W., & Vahidi, A. (2008) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.01.070 · Cited by 819
Metadata
- Authors
- Saito, M., Hayamizu, K., & Okada, T.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-01
- Volume
- 109
- Issue
- 8
- Pages
- 3112-3119
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2033234421
- Cited by
- 189
- References
- 2
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.