The DOI matches its Crossref record.
Thermal Behavior of Polyelectrolyte Multilayer Microcapsules: 2. Insight into Molecular Mechanisms for the PDADMAC/PSS System
Abstract
Polyelectrolyte multilayer capsules consisting of poly(diallyldimethylammonium chloride) (PDADMAC) and poly(styrene sulfonate) (PSS) were used as a model system to study the temperature-dependent behavior of polyelectrolyte multilayer films in aqueous media. Shells terminated with PSS shrink upon heating, whereas PDADMAC-terminated ones swell, independent of the nature of the first layer, as measured by means of confocal laser scanning microscopy (CLSM) and scanning electron microscopy (SEM). Elemental analysis shows that the initial exponential layer growth of the film leads to a nearly neutral overall charge in the first case or a high positive excess charge in the latter. Depending on this overall charge either surface tension, due to an unfavorable polymer-solvent interaction, or electrostatics dominates, resulting in a shrinkage or expansion of capsules, respectively. Thus, it is possible to swell temperature-shrunk capsules by coating them with an additional PDADMAC layer. Micro-DSC measurements prove that polyelectrolyte multilayers undergo a glass transition in water at which the wall material softens, allowing the rearrangements to occur. It is found that the thermal history has an influence on the temperature behavior of capsules, especially on those ones terminated with PDADMAC. Also, the molecular weight of the polyelectrolytes affects the rearrangement of capsules. The lower the molecular weight and thus the smaller the entanglement of chains, the easier polyelectrolytes can rearrange.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Layer-by-layer assembly of microcapsules and their biomedical applications
Tong, W., Song, X., & Gao, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35088b · Cited by 427
van Dongen, S. F. M., de Hoog, H.-P. M., Peters, R. J. R. W., Nallani, M., Nolte, R. J. M., & van Hest, J. C. M. (2009) · Chemical Reviews · doi:10.1021/cr900072y · Cited by 386
Controlled Rupture of Magnetic Polyelectrolyte Microcapsules for Drug Delivery
Hu, S.-H., Tsai, C.-H., Liao, C.-F., Liu, D.-M., & Chen, S.-Y. (2008) · Langmuir · doi:10.1021/la801138e · Cited by 268
Responsive microcapsule reactors based on hydrogen-bonded tannic acid layer-by-layer assemblies
Kozlovskaya, V., Kharlampieva, E., Drachuk, I., Cheng, D., & Tsukruk, V. V. (2010) · Soft Matter · doi:10.1039/b927369g · Cited by 267
Layer-by-layer assembled charge-trap memory devices with adjustable electronic properties
Lee, J.-S., Cho, J., Lee, C., Kim, I., Park, J., Kim, Y.-M., Shin, H., Lee, J., & Caruso, F. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.380 · Cited by 265
pH-triggered shape response of cubical ultrathin hydrogel capsules
Kozlovskaya, V., Wang, Y., Higgins, W., Chen, J., Chen, Y., & Kharlampieva, E. (2012) · Soft Matter · doi:10.1039/c2sm25641j · Cited by 53
Metadata
- Authors
- Köhler, K., Möhwald, H., & Sukhorukov, G. B.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-10-28
- Volume
- 110
- Issue
- 47
- Pages
- 24002-24010
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2021225339
- Cited by
- 163
- References
- 0
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.