The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Surface Enhanced Raman Scattering Enhancement Factors: A Comprehensive Study
Abstract
This paper presents an in-depth study of Surface Enhanced Raman Scattering (SERS) enhancement factors (EFs) and cross-sections, including several issues often overlooked. In particular, various possible rigorous definitions of the SERS EFs are introduced and discussed in the context of SERS applications, such as analytical chemistry and single molecule SERS. These definitions highlight the importance of a careful characterization of the non-SERS cross-sections of the probes under consideration. This aspect is illustrated by experimental results for the non-SERS cross-sections of representative SERS probes along with average SERS EFs for the same probes. In addition, the accurate experimental determination of single molecule enhancement factors is tackled with two recently developed techniques, namely: bi-analyte SERS (BiASERS) and temperature-dependent SERS vibrational pumping. We demonstrate that SERS EFs as low as 10 7, as opposed to the figure of 10 14 often claimed in the literature, are sufficient for the observation of single molecule SERS signals, with maximum single molecule EFs typically on the order of ∼10 10 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Cited by
Gold Nanorods: From Synthesis and Properties to Biological and Biomedical Applications
Huang, X., Neretina, S., & El‐Sayed, M. A. (2009) · Advanced Materials · doi:10.1002/adma.200802789 · Cited by 1,921
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Fan, M., Andrade, G. F. S., & Brolo, A. G. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.11.049 · Cited by 533
Single molecule analysis by surfaced-enhanced Raman scattering
Pieczonka, N. P. W., & Aroca, R. F. (2008) · Chemical Society Reviews · doi:10.1039/b709739p · Cited by 451
Guerrini, L., & Graham, D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35118h · Cited by 441
Metadata
- Authors
- Le Ru, E. C., Blackie, E., Meyer, M., & Etchegoin, P. G.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-08-23
- Volume
- 111
- Issue
- 37
- Pages
- 13794-13803
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2092049851
- Cited by
- 2,853
- References
- 2
- FWCI
- 28.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Surface Enhanced Raman Scattering Enhancement Factors: A Comprehensive Study. https://app.cochat.ai/papers/10.1021/jp0687908
- The paper
- Le Ru, E. C., Blackie, E., Meyer, M., & Etchegoin, P. G. (2007). Surface Enhanced Raman Scattering Enhancement Factors: A Comprehensive Study. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp0687908
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.