Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 195

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Detection of Structural Dynamics by FRET: A Photon Distribution and Fluorescence Lifetime Analysis of Systems with Multiple States

Kalinin, Stanislav, Valeri, Alessandro, Antonik, Matthew, Felekyan, Suren, Seidel, Claus A. M.·2010·The Journal of Physical Chemistry B

Abstract

Two complementary methods in confocal single-molecule fluorescence spectroscopy are presented to analyze conformational dynamics by Forster resonance energy transfer (FRET) measurements considering simulated and experimental data. First, an extension of photon distribution analysis (PDA) is applied to characterize conformational exchange between two or more states via global analysis of the shape of FRET peaks for different time bins. PDA accurately predicts the shape of FRET efficiency histograms in the presence of FRET fluctuations, taking into account shot noise and background contributions. Dynamic-PDA quantitatively recovers FRET efficiencies of the interconverting states and relaxation times of dynamics on the time scale of the diffusion time t(d) (typically milliseconds), with a dynamic range of the method of about +/-1 order of magnitude with respect to t(d). Correction procedures are proposed to consider the factors limiting the accuracy of dynamic-PDA, such as brightness variations, shortening of the observation time due to diffusion, and a contribution of multimolecular events. Second, an analysis procedure for multiparameter fluorescence detection is presented, where intensity-derived FRET efficiency is correlated with the fluorescence lifetime of the donor quenched by FRET. If a maximum likelihood estimator is applied to compute a mean fluorescence lifetime of mixed states, one obtains a fluorescence weighted mean lifetime. Thus a mixed state is detected by a characteristic shift of the fluorescence lifetime, which becomes longer than that expected for a single species with the same intensity-derived FRET efficiency. Analysis tools for direct visual inspection of two-dimensional diagrams of FRET efficiency versus donor lifetime are presented for the cases of static and dynamic FRET. Finally these new techniques are compared with fluorescence correlation spectroscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp102156t

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 195

Metadata

Authors
Kalinin, S., Valeri, A., Antonik, M., Felekyan, S., & Seidel, C. A. M.
Venue
The Journal of Physical Chemistry B
Published
2010-05-20
Volume
114
Issue
23
Pages
7983-7995
ISSN
  • 1520-5207 (ISSN-L)
  • 1520-6106
OpenAlex
W2073341329
Cited by
195
References
1
FWCI
7.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.