The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor
Abstract
A novel fabrication approach of a highly sensitive amperometric glucose biosensor based on a single ZnO nanofiber (ZONF) is presented. Nanofibers (NFs) of poly(vinyl pyrrolidone)/zinc acetate composite have been synthesized by electrospinning technique. By high-temperature calcinations of the above precursor fibers, ZONFs with diameters in the range of 350−195 nm have been successfully obtained. A single NF on a gold electrode is functionalized with glucose oxidase (GOx) by physical adsorption. Electrochemical measurements of the biosensor revealed a high and reproducible sensitivity of 70.2 μA cm −2 mM −1 within a response time of less than 4 s. The biosensor also showed a linear range from 0.25 to 19 mM with a low limit of detection (LOD) of 1 μM. Furthermore, it has been revealed that the biosensor exhibits a good anti-interference ability and favorable stability over relatively long-term storage (more than 4 months). All these results strongly suggest that a single ZONF can provide a new platform for biosensor design and other biological applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward a Glucose Biosensor Based on Surface-Enhanced Raman Scattering
Shafer-Peltier, K. E., Haynes, C. L., Glucksberg, M. R., & Van Duyne, R. P. (2003) · Journal of the American Chemical Society · doi:10.1021/ja028255v · Cited by 653
Cited by
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Wearable flexible sweat sensors for healthcare monitoring: a review
Chung, M., Fortunato, G., & Radacsi, N. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0217 · Cited by 378
Electrospun Fibrous Architectures for Drug Delivery, Tissue Engineering and Cancer Therapy
Ding, Y., Li, W., Zhang, F., Liu, Z., Zanjanizadeh Ezazi, N., Liu, D., & Santos, H. A. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201802852 · Cited by 312
Supraja, P., Sudarshan, V., Tripathy, S., Agrawal, A., & Singh, S. G. (2019) · Analytical Methods · doi:10.1039/c8ay02617c · Cited by 45
Metadata
- Authors
- Ahmad, M., Pan, C., Luo, Z., & Zhu, J.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-03
- Volume
- 114
- Issue
- 20
- Pages
- 9308-9313
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2085096838
- Cited by
- 229
- References
- 1
- FWCI
- 12.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor. https://app.cochat.ai/papers/10.1021/jp102505g
- The paper
- Ahmad, M., Pan, C., Luo, Z., & Zhu, J. (2010). A Single ZnO Nanofiber-Based Highly Sensitive Amperometric Glucose Biosensor. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp102505g