Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Development of an Amperometric Cholesterol Biosensor Based on Graphene−Pt Nanoparticle Hybrid Material

Dey, Ramendra Sundar, Raj, C. Retna·2010·The Journal of Physical Chemistry C

Abstract

We describe the development of a highly sensitive amperometric biosensor based on the hybrid material derived from nanoscale Pt particles (nPt) and graphene for the sensing of H 2 O 2 and cholesterol. The biosensing platform was developed using the hybrid material and enzymes cholesterol oxidase and cholesterol esterase. Chemically synthesized graphene has been decorated with nanosized Pt particles. The electron microscopic measurements show that the Pt nanoparticles on graphene have an average size of 12 nm and are randomly distributed throughout the surface. The Pt nanoparticle based hybrid material modified electrode efficiently catalyzes the electrochemical oxidation of H 2 O 2 at the potential of 0.4 V, which is >100 mV less positive with respect to the bulk Pt electrode. The sensing platform is highly sensitive and shows linear response toward H 2 O 2 up to 12 mM with a detection limit of 0.5 nM [S/N (signal-to-noise ratio) = 3] in the absence of any redox mediator or enzyme. The combination of electronically highly conductive graphene and catalytically active Pt nanoparticle favors the facilitated electron transfer for the oxidation of H 2 O 2 . The cholesterol biosensor was developed by immobilizing cholesterol oxidase and cholesterol esterase on the surface of graphene−nanoparticle hybrid material. The bienzyme integrated nanostructured platform is very sensitive, selective toward cholesterol, and it has a fast response time. The sensitivity and limit of detection of the electrode toward cholesterol ester are 2.07 ± 0.1 μA/μM/cm 2 and 0.2 μM, respectively. The apparent Michaelis−Menten constant ( K m app ) was calculated to be 5 mM. The sensor does not suffer from the interference due to other common electroactive species and is highly stable. The analytical performance of the hybrid material was further evaluated using screen-printed electrodes with 50 μL of electrolyte.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp105895a

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 299

Metadata

Authors
Dey, R. S., & Raj, C. R.
Venue
The Journal of Physical Chemistry C
Published
2010-11-17
Volume
114
Issue
49
Pages
21427-21433
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2068236561
Cited by
299
References
2
FWCI
20.43
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.