The DOI matches its Crossref record.
Study on Polymer Binders for High-Capacity SiO Negative Electrode of Li-Ion Batteries
Abstract
High-capacity SiO powder composite electrodes for rechargeable lithium-ion batteries are prepared with different polymer binders of poly(acrylic acid) (PAA), poly(vinyl alcohol) (PVA), sodium carboxymethyl cellulose (CMCNa), and conventional poly(vinylidene fluoride) (PVdF). Electrode performance of the SiO composites highly depends on selection of binders, and their electrochemical reversibility is drastically improved by using PAA as the binder in comparison to the PVdF, CMCNa, and PVA binders. Coulombic efficiency at the initial cycle is improved for the SiO–PAA composite electrode, and the reversible capacity reaches 700–750 mAh g –1 for continuous fifty cycling test at a rate of 100 mA g –1 . The improvement mechanism of SiO–PAA composite electrode is characterized by X-ray diffraction, electron microscopy, X-ray photoelectron spectroscopy, infrared spectroscopy, self-discharge test, and adhesive strength test. Amorphous PAA polymer not only tightly binds but also covers the individual SiO particles. Moreover, the PAA binder suppresses swelling of the composite electrode with the electrolyte solution compared to the PVdF binder. Through-thickness electric resistance of the PAA composite electrode is much lower than that of the PVdF when it is wet with the electrolyte. It is proposed that these characters of the PAA binder effectively suppress isolation of the SiO powders in the composite electrode associated with the large volume expansion/shrinkage during the lithiation/delithiation processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Komaba, S., Murata, W., Ishikawa, T., Yabuuchi, N., Ozeki, T., Nakayama, T., Ogata, A., Gotoh, K., & Fujiwara, K. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201100854 · Cited by 2,116
Self-citationAn Amorphous Red Phosphorus/Carbon Composite as a Promising Anode Material for Sodium Ion Batteries
Kim, Y., Park, Y., Choi, A., Choi, N., Kim, J., Lee, J., Ryu, J. H., Oh, S. M., & Lee, K. T. (2013) · Advanced Materials · doi:10.1002/adma.201204877 · Cited by 854
Ionic liquids and derived materials for lithium and sodium batteries
Yang, Q., Zhang, Z., Sun, X.-G., Hu, Y.-S., Xing, H., & Dai, S. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00464h · Cited by 601
High energy density calendered Si alloy/graphite anodes
Du, Z., Dunlap, R. A., & Obrovac, M. N. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0941410jes · Cited by 107
Metadata
- Authors
- Komaba, S., Shimomura, K., Yabuuchi, N., Ozeki, T., Yui, H., & Konno, K.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-06-17
- Volume
- 115
- Issue
- 27
- Pages
- 13487-13495
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2312689500
- Cited by
- 405
- References
- 0
- FWCI
- 14.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Study on Polymer Binders for High-Capacity SiO Negative Electrode of Li-Ion Batteries. https://app.cochat.ai/papers/10.1021/jp201691g
- The paper
- Komaba, S., Shimomura, K., Yabuuchi, N., Ozeki, T., Yui, H., & Konno, K. (2011). Study on Polymer Binders for High-Capacity SiO Negative Electrode of Li-Ion Batteries. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp201691g
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.