The DOI matches its Crossref record.
How Is Charge Transport Different in Ionic Liquids and Electrolyte Solutions?
Abstract
In this article we show that, analyzed in a barycentric reference frame, the deviation in conductivity measured directly from impedance experiments with respect to that estimated indirectly from NMR diffusion experiments has different origins in electrolyte solutions and pure salts. In the case of electrolyte solutions, the momentum conservation law is satisfied by solvent + ions. Instead, in a molten salt or ionic liquid momentum conservation must be satisfied solely by the ions. This has significant implications. While positively correlated motion of ions of opposite charge is a well justified explanation for the reduction in impedance conductivity in the case of electrolyte solutions, it is not so in the case of ionic liquids and molten salts. This work presents a set of equations that in the case of ionic liquids and molten salts can be used to obtain from direct measurements of impedance and NMR the distinct part of the diffusion coefficient matrix in the barycentric reference frame. In other words, by using experimentally measurable quantities, these equations allow us to access the motional coupling between ions for which there is no single direct experimental measurement technique. While equations of this type have been proposed before, the ones presented here can be easily derived from the momentum conservation law and linear response theory. Our results indicate that the decrease in the impedance conductivity with respect to NMR conductivity in ionic liquids and molten salts is due to anticorrelated motion of ions of same charge. This scenario is different in electrolyte solutions, where the positively correlated motion of ions of opposite charge makes a significant contribution to the decrease in the impedance conductivity. In contrast, in a system comprising a single binary salt (a room temperature ionic liquid or a molten salt), the cation-anion distinct diffusion coefficient is negative definite and opposes the contribution from the cation-cation and anion-anion distinct diffusion coefficients. This property of the cation-anion distinct diffusion coefficient in systems comprising just two ion-constituents holds true not just in the barycentric reference frame but also in any of the internal reference frames of nonequilibrium thermodynamics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perspectives for Polymer Electrolytes: A View from Fundamentals of Ionic Conductivity
Bocharova, V., & Sokolov, A. P. (2020) · Macromolecules · doi:10.1021/acs.macromol.9b02742 · Cited by 499
Ion Dissociation in Ionic Liquids and Ionic Liquid Solutions
Nordness, O., & Brennecke, J. F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00373 · Cited by 488
Microstructural and Dynamical Heterogeneities in Ionic Liquids
Wang, Y.-L., Li, B., Sarman, S., Mocci, F., Lu, Z.-Y., Yuan, J., Laaksonen, A., & Fayer, M. D. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00693 · Cited by 465
Fong, K. D., Self, J., Diederichsen, K. M., Wood, B. M., McCloskey, B. D., & Persson, K. A. (2019) · ACS Central Science · doi:10.1021/acscentsci.9b00406 · Cited by 239
Metadata
- Authors
- Kashyap, H. K., Annapureddy, H. V. R., Raineri, F. O., & Margulis, C. J.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-24
- Volume
- 115
- Issue
- 45
- Pages
- 13212-13221
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W2040716987
- Cited by
- 247
- References
- 0
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.