The DOI matches its Crossref record.
Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid
Abstract
The accurate measurement of the gaseous sulfuric acid concentration is crucial within many fields of atmospheric science. Instruments utilizing chemical ionization mass spectrometry (CIMS) measuring H(2)SO(4), therefore, require a careful calibration. We have set up a calibration source that can provide a stable and adjustable concentration of H(2)SO(4). The calibration system initiates the production of sulfuric acid through the oxidation of SO(2) by OH. The hydroxyl radical is produced by UV photolysis of water vapor. A numerical model calculates the H(2)SO(4) concentration provided at the outlet of the calibration source. From comparison of this concentration and the signals measured by CIMS, a calibration factor is derived. This factor is evaluated to be 1.1 × 10(10) cm(-3), which is in good agreement with values found in the literature for other CIMS instruments measuring H(2)SO(4). The calibration system is described in detail and the results are discussed. Because the setup is external to the CIMS instrument, it offers the possibility for future CIMS intercomparison measurements by providing defined and stable concentrations of sulfuric acid.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bianchi, F., Kurtén, T., Riva, M., Mohr, C., Rissanen, M. P., Roldin, P., Berndt, T., Crounse, J. D., Wennberg, P. O., Mentel, T. F., et al. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00395 · Cited by 1,084
Molecular understanding of sulphuric acid–amine particle nucleation in the atmosphere
Almeida, J., Schobesberger, S., Kürten, A., Ortega, I. K., Kupiainen-Määttä, O., Praplan, A. P., Adamov, A., Amorim, A., Bianchi, F., Breitenlechner, M., et al. (2013) · Nature · doi:10.1038/nature12663 · Cited by 1,027
Self-citationThe role of low-volatility organic compounds in initial particle growth in the atmosphere
Tröstl, J., Chuang, W. K., Gordon, H., Heinritzi, M., Yan, C., Molteni, U., Ahlm, L., Frege, C., Bianchi, F., Wagner, R., et al. (2016) · Nature · doi:10.1038/nature18271 · Cited by 850
Self-citationIon-induced nucleation of pure biogenic particles
Kirkby, J., Duplissy, J., Sengupta, K., Frege, C., Gordon, H., Williamson, C., Heinritzi, M., Simon, M., Yan, C., Almeida, J., et al. (2016) · Nature · doi:10.1038/nature17953 · Cited by 793
Self-citationNew particle formation in the free troposphere: A question of chemistry and timing
Bianchi, F., Tröstl, J., Junninen, H., Frege, C., Henne, S., Hoyle, C. R., Molteni, U., Herrmann, E., Adamov, A., Bukowiecki, N., et al. (2016) · Science · doi:10.1126/science.aad5456 · Cited by 546
Self-citation
Metadata
- Authors
- Kürten, A., Rondo, L., Ehrhart, S., & Curtius, J.
- Venue
- The Journal of Physical Chemistry A
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-14
- Volume
- 116
- Issue
- 24
- Pages
- 6375-6386
- ISSN
- 1089-5639 (ISSN-L)
- 1520-5215
- OpenAlex
- W2331041989
- Cited by
- 245
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid. https://app.cochat.ai/papers/10.1021/jp212123n
- The paper
- Kürten, A., Rondo, L., Ehrhart, S., & Curtius, J. (2012). Calibration of a Chemical Ionization Mass Spectrometer for the Measurement of Gaseous Sulfuric Acid. The Journal of Physical Chemistry A. https://doi.org/10.1021/jp212123n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.