The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Improved Hydrogen Storage and Thermal Conductivity in High-Density MOF-5 Composites
Abstract
Porous adsorbents such as MOF-5 have low thermal conductivities which can limit the performance of adsorption-based hydrogen storage systems. To improve the thermal properties of these materials, we have prepared a series of high-density MOF-5 composites containing 0–10 wt % expanded natural graphite (ENG), which serves as a thermal conduction enhancer. The addition of 10 wt % ENG to MOF-5 and compaction to 0.5 g/cm 3 was previously found to increase the thermal conductivity relative to neat MOF-5 of the same density by a factor of 5. In this study, detailed measurements of the hydrogen storage behavior of MOF-5/ENG composites between 77 and 295 K are reported. We find that MOF-5 pellets with 0 wt % ENG and a density of 0.5 g/cm 3 have a total volumetric hydrogen storage density at 77 K and 100 bar that is 23% larger than powder MOF-5 and 41% larger than cryo-compressed hydrogen. The addition of 10% ENG to 0.5 g/cm 3 MOF-5 pellets produces only a small decrease (6%) in the total volumetric hydrogen storage compared to neat MOF-5 pellets of equal density. The excess, absolute, total, and deliverable hydrogen storage amounts by the MOF-5 composites are compared for ENG additions of 0–10 wt % and pellet densities of 0.3–0.7 g/cm 3 . Three adsorption models (Unilan, Tóth, Dubinin–Astakhov) are compared for their effectiveness in describing hydrogen adsorption isotherms of MOF-5 and MOF-5/ENG composites. The Unilan model provides the most accurate description of the experimental data, requiring only five temperature-invariant parameters to accurately fit the data across a wide temperature range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Structure of a Catalyst Surface
Sips, R. (1948) · The Journal of Chemical Physics · doi:10.1063/1.1746922 · Cited by 3,650
Fundamental Equations of State for Parahydrogen, Normal Hydrogen, and Orthohydrogen
Leachman, J. W., Jacobsen, R. T., Penoncello, S. G., & Lemmon, E. W. (2009) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.3160306 · Cited by 822
A Review of Heat Transfer Issues in Hydrogen Storage Technologies
Zhang, J., Fisher, T. S., Ramachandran, P. V., Gore, J. P., & Mudawar, I. (2005) · Journal of Heat Transfer · doi:10.1115/1.2098875 · Cited by 201
Cited by
Ren, J., Musyoka, N. M., Langmi, H. W., Mathe, M., & Liao, S. (2017) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2016.11.195 · Cited by 707
Langmuir’s Theory of Adsorption: A Centennial Review
Swenson, H., & Stadie, N. P. (2019) · Langmuir · doi:10.1021/acs.langmuir.9b00154 · Cited by 646
Qin, J., Wang, S., & Wang, X. (2017) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2017.03.018 · Cited by 637
Adsorption, separation, and catalytic properties of densified metal-organic frameworks
Nandasiri, M. I., Jambovane, S. R., McGrail, B. P., Schaef, H. T., & Nune, S. K. (2016) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2015.12.004 · Cited by 324
CO2 Capture in Metal–Organic Framework Adsorbents: An Engineering Perspective
Hu, Z., Wang, Y., Shah, B. B., & Zhao, D. (2019) · Advanced Sustainable Systems · doi:10.1002/adsu.201800080 · Cited by 297
Metadata
- Authors
- Purewal, J., Liu, D., Sudik, A., Veenstra, M., Yang, J., Maurer, S., Müller, U., & Siegel, D. J.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-09-13
- Volume
- 116
- Issue
- 38
- Pages
- 20199-20212
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2320633538
- Cited by
- 167
- References
- 3
- FWCI
- 5.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.