The DOI matches its Crossref record.
Nanoparticle Location and Material-Dependent Dose Enhancement in X-ray Radiation Therapy
Open accessAbstract
Nanoparticles of high atomic number (Z) materials can act as radiosensitizers to enhance radiation dose delivered to tumors. An analytical approach is used to calculate dose enhancements to tumor endothelial cells and their nuclei for a series of nanoparticles (bismuth, gold and platinum) located at different locations relative to nuclei by considering contributions from both photoelectrons and Auger electrons. The ratio of the dose delivered to cells with and without the nanoparticles is known as the dose enhancement factor (DEF). DEFs depend on material composition, size and location of nanoparticles with respect to the cell and the nucleus. Energy of irradiating X-ray beam affects X-ray absorption by nanoparticles and plays an important role in dose enhancements. For diagnostic X-ray sources, bismuth nanoparticles provide higher dose enhancements than gold and platinum nanoparticles for a given nanoparticle size, concentration and location. The highest DEFs are achieved for nanoparticles located closest to the nucleus where energy depositions from short range Auger electrons are maximum. With nanoparticles ranging in diameter between 2-400 nm, the dose enhancement increases with decrease in particle size. The results are useful in finding optimized conditions for nanoparticle enhanced X-ray radiation therapy of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chen, Y., Chen, H., & Shi, J. (2013) · Advanced Materials · doi:10.1002/adma.201205292 · Cited by 724
Shahbazi, M.-A., Faghfouri, L., Ferreira, M. P. A., Figueiredo, P., Maleki, H., Sefat, F., Hirvonen, J., & Santos, H. A. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00283a · Cited by 523
Gold nanoparticles for cancer radiotherapy: a review
Haume, K., Rosa, S., Grellet, S., Śmiałek, M. A., Butterworth, K. T., Solov’yov, A. V., Prise, K. M., Golding, J., & Mason, N. J. (2016) · Cancer Nanotechnology · doi:10.1186/s12645-016-0021-x · Cited by 445
Deng, J., Xu, S., Hu, W., Xun, X., Zheng, L., & Su, M. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.048 · Cited by 234
Self-citationMagneto‐Plasmonic Au‐Fe Alloy Nanoparticles Designed for Multimodal SERS‐MRI‐CT Imaging
Amendola, V., Scaramuzza, S., Litti, L., Meneghetti, M., Zuccolotto, G., Rosato, A., Nicolato, E., Marzola, P., Fracasso, G., Anselmi, C., et al. (2014) · Small · doi:10.1002/smll.201303372 · Cited by 189
Metadata
- Authors
- Hossain, M., & Su, M.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-10-19
- Volume
- 116
- Issue
- 43
- Pages
- 23047-23052
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2057070832
- Cited by
- 183
- References
- 0
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoparticle Location and Material-Dependent Dose Enhancement in X-ray Radiation Therapy. https://app.cochat.ai/papers/10.1021/jp306543q
- The paper
- Hossain, M., & Su, M. (2012). Nanoparticle Location and Material-Dependent Dose Enhancement in X-ray Radiation Therapy. The Journal of Physical Chemistry C. https://doi.org/10.1021/jp306543q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.