The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Differential Capacitance of the Electrical Double Layer in Imidazolium-Based Ionic Liquids: Influence of Potential, Cation Size, and Temperature
Abstract
The interfaces formed at glassy carbon electrodes in three low-temperature ionic liquids (1-methyl-3-ethylimidazolium chloride, emimCl; 1-methyl-3-butylimidazolium chloride, bmimCl; and 1-methyl-3-hexylimidazolium chloride, hmimCl) were investigated by cyclic voltammetry and impedance spectroscopy. The potential dependence of the differential double layer capacitance was measured at several temperatures between 80 and 140 °C, and the temperature response was found to be broadly similar to that obtained with high-temperature molten salts. The differential capacitance/potential curves have a minimum and two side branches. The minimum corresponds to the point of zero charge. The differential capacitance increases in the order hmimCl < bmimCl < emimCl because the double layer is thinner when imidazolium (Rmim) cations with shorter alkyl chain lengths are used. The impedance spectra and capacitance curves indicate that cations are adsorbed at the open-circuit potential and that their surface excess concentration increases with negative polarization. Adsorption of the cation becomes stronger as the length of the alkyl chain decreases. Adsorption of chloride anions occurs at positive potentials and is weakest with bmimCl. The increase in the differential capacitance with temperature is most probably due to ion association within the double layer, which diminishes as temperature increases. The electrochemical window narrows as the temperature increases but is almost unaffected by the length of the alkyl chain of the Rmim cation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of chloride, water, and organic solvents on the physical properties of ionic liquids
Seddon, K. R., Stark, A., & Torres, M.-J. (2000) · Pure and Applied Chemistry · doi:10.1351/pac200072122275 · Cited by 2,293
Predicting physical properties of ionic liquids
Deetlefs, M., Seddon, K. R., & Shara, M. (2006) · Phys. Chem. Chem. Phys. · doi:10.1039/b513453f · Cited by 411
Cited by
Structure and Nanostructure in Ionic Liquids
Hayes, R., Warr, G. G., & Atkin, R. (2015) · Chemical Reviews · doi:10.1021/cr500411q · Cited by 2,293
Double Layer in Ionic Liquids: Overscreening versus Crowding
Bazant, M. Z., Storey, B. D., & Kornyshev, A. A. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.046102 · Cited by 1,098
Electrolyte‐Gated Transistors for Organic and Printed Electronics
Kim, S. H., Hong, K., Xie, W., Lee, K. H., Zhang, S., Lodge, T. P., & Frisbie, C. D. (2013) · Advanced Materials · doi:10.1002/adma.201202790 · Cited by 957
Dai, H., Xi, K., Liu, X., Lai, C., & Zhang, S. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b08963 · Cited by 283
Self-assembly in the electrical double layer of ionic liquids
Perkin, S., Crowhurst, L., Niedermeyer, H., Welton, T., Smith, A. M., & Gosvami, N. N. (2011) · Chemical Communications · doi:10.1039/c1cc11322d · Cited by 277
Highly deformable liquid-state heterojunction sensors
Ota, H., Chen, K., Lin, Y., Kiriya, D., Shiraki, H., Yu, Z., Ha, T.-J., & Javey, A. (2014) · Nature Communications · doi:10.1038/ncomms6032 · Cited by 264
Huang, J. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.7b11093 · Cited by 27
Metadata
- Authors
- Lockett, V., Sedev, R., Ralston, J., Horne, M., & Rodopoulos, T.
- Venue
- The Journal of Physical Chemistry C
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-19
- Volume
- 112
- Issue
- 19
- Pages
- 7486-7495
- ISSN
- 1932-7447 (ISSN-L)
- 1932-7455
- OpenAlex
- W2015534088
- Cited by
- 515
- References
- 2
- FWCI
- 12.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.