Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 202

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

ZnO Nanotube Arrays as Biosensors for Glucose

Yang, Kun, She, Guang-Wei, Wang, Hui, Ou, Xue-Mei, Zhang, Xiao-Hong, Lee, Chun-Sing, Lee, Shuit-Tong·2009·The Journal of Physical Chemistry C

Abstract

Highly oriented single-crystal ZnO nanotube (ZNT) arrays were prepared by a two-step electrochemical/chemical process on indium-doped tin oxide (ITO) coated glass in an aqueous solution. The prepared ZNT arrays were further used as a working electrode to fabricate an enzyme-based glucose biosensor through immobilizing glucose oxidase in conjunction with a Nafion coating. The present ZNT arrays-based biosensor exhibits high sensitivity of 30.85 μA cm −2 mM −1 at an applied potential of +0.8 V vs. SCE, wide linear calibration ranges from 10 μM to 4.2 mM, and a low limit of detection (LOD) at 10 μM (measured) for sensing of glucose. The apparent Michaelis−Menten constant K M app was calculated to be 2.59 mM, indicating a higher bioactivity for the biosensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jp901894j

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 202

Metadata

Authors
Yang, K., She, G.-W., Wang, H., Ou, X.-M., Zhang, X.-H., Lee, C.-S., & Lee, S.-T.
Venue
The Journal of Physical Chemistry C
Published
2009-11-02
Volume
113
Issue
47
Pages
20169-20172
ISSN
  • 1932-7447 (ISSN-L)
  • 1932-7455
OpenAlex
W2012695022
Cited by
202
References
2
FWCI
13.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.