Poly(ε-caprolactone)/Poly(ethylene glycol)/Poly(ε-caprolactone) Nanoparticles: Preparation, Characterization, and Application in Doxorubicin Delivery
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Biodegradable poly(epsilon-caprolactone)/poly(ethylene glycol) (PCL/PEG) copolymer nanoparticles showed potential application in drug delivery systems. In this article, monodisperse poly(epsilon-caprolactone)/poly(ethylene glycol)/poly(epsilon-caprolactone) (PCL/PEG/PCL, PCEC) nanoparticles, approximately 40 nm, were prepared by solvent extraction method using acetone as the organic solvent. These PCL/PEG/PCL nanoparticles did not induce hemolysis in vitro and did not show toxicity in vitro or in vivo. The prepared PCL/PEG/PCL nanoparticles were employed to load doxorubicin by a pH-induced self-assembly method. In vitro release study indicated that doxorubicin release from nanoparticles at pH 5.5 was faster than that at pH 7.0. The encapsulation of doxorubicin in PCL/PEG/PCL nanoparticles enhanced the cytotoxicity of doxorubicin on a C-26 cell line in vitro. Meanwhile, compared with free doxorubicin, doxorubicin in nanoparticles could more efficiently treat mice bearing subcutaneous C-26 tumors. The doxorubicin-loaded PCL/PEG/PCL nanoparticles might be a novel doxorubicin formulation for cancer therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers as biomaterials
Nair, L. S., & Laurencin, C. T. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.017 · Cited by 4,416
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438
Bae, Y., Fukushima, S., Harada, A., & Kataoka, K. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200250653 · Cited by 1,329
Polymeric nanomedicine for cancer therapy
Park, J. H., Lee, S., Kim, J.-H., Park, K., Kim, K., & Kwon, I. C. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.09.003 · Cited by 506
Multi-functional nanocarriers to overcome tumor drug resistance
Jabr-Milane, L. S., van Vlerken, L. E., Yadav, S., & Amiji, M. M. (2008) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2008.04.003 · Cited by 407
Cited by
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Gao, Y., Chen, Y., Ji, X., He, X., Yin, Q., Zhang, Z., Shi, J., & Li, Y. (2011) · ACS Nano · doi:10.1021/nn2033105 · Cited by 400
Matanović, M. R., Kristl, J., & Grabnar, P. A. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.06.029 · Cited by 247
“…composed of hydrophilic polyethylene oxide (PEO) and hydrophobic poly(e-caprolactone) (PCL), PCL–PEO–PCL, which form a thermoresponsive in situ-forming, and biodegradable hydrogel, have also been studied as drug delivery systems (Gong et al., 2009a,b; Gou et al., 2009; Zhou et al., 2003).”
BackgroundKrukiewicz, K., & Zak, J. K. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.01.063 · Cited by 193
The Rise and Rise of Stealth Nanocarriers for Cancer Therapy: Passive Versus Active Targeting
Huynh, N. T., Roger, E., Lautram, N., Benoît, J.-P., & Passirani, C. (2010) · Nanomedicine · doi:10.2217/nnm.10.113 · Cited by 164
Metadata
- Authors
- Gou, M., Zheng, X., Men, K., Zhang, J., Zheng, L., Wang, X., Luo, F., Zhao, Y., Zhao, X., Wei, Y., & Qian, Z.
- Venue
- The Journal of Physical Chemistry B
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-09-09
- Volume
- 113
- Issue
- 39
- Pages
- 12928-12933
- ISSN
- 1520-5207 (ISSN-L)
- 1520-6106
- OpenAlex
- W1998269448
- Cited by
- 79
- References
- 5
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.