Development of a single‐shot subunit vaccine for HIV‐1. 5. Programmable in vivo autoboost and long lasting neutralizing response
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The subunit vaccine for HIV-1, recombinant glycoprotein 120 (rgp120), was used as a model antigen to evaluate the potential for a pulsatile single immunization vaccine formulation consisting of poly(lactic-co-glycolic) acid (PLGA) microspheres. We designed rgp120 PLGA microsphere formulations that provide a pulse of rgp120 at 1 to 6 months (depending on the polymer) after administration, mimicking another immunization. In these studies, the in vitro pulse of rgp120 correlated well with the observed in vivo autoboost as measured by an increase in anti-gp120 antibodies in guinea pigs. The immune response to the rgp120 PLGA microsphere formulations was increased by adding the soluble form of the saponin-derived adjuvant, QS-21. The use of small microspheres, however, did not increase the humoral response to rgp120. A single immunization with rgp120 PLGA microspheres resuspended in soluble rgp120 and QS-21 elicited neutralizing antibody titers that were comparable to titers obtained from two immunizations of rgp120 and QS-21 at the same total dose. Administration of rgp120 PLGA microspheres in baboons resulted in high, long-lasting neutralizing antibody titers that were greater than repeated immunizations with soluble rgp120 and QS-21. These studies also indicated that a continuous release of QS-21 at the injection site may provide a greater immune response than a bolus injection. Overall, this work demonstrated that PLGA microsphere formulations may be designed to provide in vivo pulses of an antigen eliminating the need for repeated immunizations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Cited by
Microspheres for controlled release drug delivery
Varde, N. K., & Pack, D. W. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.1.35 · Cited by 448
Controlled drug delivery in tissue engineering
Biondi, M., Ungaro, F., Quaglia, F., & Netti, P. A. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.08.038 · Cited by 412
Drug delivery systems for programmed and on-demand release
Davoodi, P., Lee, L. Y., Xu, Q., Sunil, V., Sun, Y., Soh, S., & Wang, C.-H. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.002 · Cited by 353
Gutierro, I., Hernández, R. M., Igartua, M., Gascón, A. R., & Pedraz, J. L. (2002) · Vaccine · doi:10.1016/s0264-410x(02)00435-8 · Cited by 292
Revisiting PLA/PLGA microspheres: an analysis of their potential in parenteral vaccination
Johansen, P. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00079-5 · Cited by 210
“Programmed polymeric devices” for pulsed drug delivery
Stubbe, B. G., De Smedt, S. C., & Demeester, J. (2004) · Pharmaceutical Research · doi:10.1023/b:pham.0000045223.45400.01 · Cited by 84
Schöll, I., Boltz-Nitulescu, G., & Jensen-Jarolim, E. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.12.020 · Cited by 51
Walter, F., Schöll, I., Untersmayr, E., Ellinger, A., Boltz-Nitulescu, G., Scheiner, O., Gabor, F., & Jensen-Jarolim, E. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2004.01.057 · Cited by 47
Metadata
- Authors
- Cleland, J. L., Lim, A., Daugherty, A., Barron, L., Desjardin, N., Duenas, E. T., Eastman, D. J., Vennari, J. C., Wrin, T., Berman, P., Murthy, K. K., & Powell, M. F.
- Venue
- Journal of Pharmaceutical Sciences
- Publisher
- American Geophysical Union (AGU)
- Published
- 1998-12
- Volume
- 87
- Issue
- 12
- Pages
- 1489-1495
- ISSN
- 0022-3549 (ISSN-L)
- OpenAlex
- W2167126715
- Cited by
- 38
- References
- 1
- FWCI
- 0.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.