The DOI matches its Crossref record.
Effects of the Excitation Wavelength on the SERS Spectrum
Abstract
SERS is nowadays a well-established ultrasensitive technique with potential to solve many analytical problems, especially those related to biosciences. This Perspective article aims at summarizing the experimental complexities, in particular, those related to the interaction of light with the sample, that the SERS practitioner may find when acquiring a spectrum while providing a general basis for the interpretation of the obtained vibrational features. With such an idea in mind, factors related to the instrumentation, the optical enhancer, and the analyte molecule are discussed to illustrate the effects of the incident light on the absolute and relative intensity, as well as the spectral profile of the SERS spectra.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fornasaro, S., Alsamad, F., Baia, M., Batista de Carvalho, L. A. E., Beleites, C., Byrne, H. J., Chiadò, A., Chis, M., Chisanga, M., Daniel, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05658 · Cited by 124
Metadata
- Authors
- Álvarez-Puebla, R. A.
- Venue
- The Journal of Physical Chemistry Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-14
- Volume
- 3
- Issue
- 7
- Pages
- 857-866
- ISSN
- 1948-7185 (ISSN-L)
- OpenAlex
- W2314634877
- Cited by
- 277
- References
- 0
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of the Excitation Wavelength on the SERS Spectrum. https://app.cochat.ai/papers/10.1021/jz201625j
- The paper
- Álvarez-Puebla, R. A. (2012). Effects of the Excitation Wavelength on the SERS Spectrum. The Journal of Physical Chemistry Letters. https://doi.org/10.1021/jz201625j
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.