The DOI matches its Crossref record.
Reactive Polymer Coatings: A Platform for Patterning Proteins and Mammalian Cells onto a Broad Range of Materials
Abstract
We report a procedure for surface modification based on chemical vapor deposition polymerization of functionalized [2.2]paracyclophanes that is essentially substrate-independent. Poly( p- xylylene-2,3-dicarboxylic anhydride) and poly[ p -xylylene carboxylic acid pentafluorophenolester- co - p -xylylene] are examined as templates for cell patterning. Both reactive coatings are deposited on poly(tetrafluoroethylene), polyethylene, silicon, gold, stainless steel, and glass and show excellent adhesion when deposited in thin films (ca. 100 nm) under optimized polymerization conditions. X-ray photoelectron spectroscopy and grazing angle infrared spectroscopy have been used to confirm chemical homogeneity in both cases. Reactive coatings are subsequently patterned by microcontact printing of an amino-terminated biotin ligand and serve as templates for layer-by-layer self-assembly. Streptavidin selectively binds to the biotin-exposing surface regions and allows surface confinement of a biotin-tethered antibody against α 5 -integrin. The specific interaction of this antibody with endothelial cells results in spatially directed deposition of mammalian cells. Fluorescence microscopy is used to verify accurate self-assembly at each step. Although both reactive coatings differ in how they chemically bind biomolecules, their ability to support formation of pattern by microcontact printing is similar.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface engineering approaches to micropattern surfaces for cell-based assays
Falconnet, D., Csucs, G., Michelle Grandin, H., & Textor, M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.024 · Cited by 944
Das, A., & Theato, P. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00291 · Cited by 483
Chemical Vapor Deposition of Conformal, Functional, and Responsive Polymer Films
Alf, M. E., Asatekin, A., Barr, M. C., Baxamusa, S. H., Chelawat, H., Ozaydin‐Ince, G., Petruczok, C. D., Sreenivasan, R., Tenhaeff, W. E., Trujillo, N. J., et al. (2010) · Advanced Materials · doi:10.1002/adma.200902765 · Cited by 399
Superhydrophilic (superwetting) surfaces: A review on fabrication and application
Otitoju, T. A., Ahmad, A. L., & Ooi, B. S. (2017) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2016.12.016 · Cited by 298
Functionalized synthetic biodegradable polymer scaffolds for tissue engineering.
Liu, X., Holzwarth, J. M., & Ma, P. X. (2012) · Macromolecular Bioscience · doi:10.1002/mabi.201100466 · Cited by 290
Synthesis of well‐defined polymeric activated esters
Theato, P. (2008) · Journal of Polymer Science Part A: Polymer Chemistry · doi:10.1002/pola.22994 · Cited by 287
Suh, K. Y., Seong, J., Khademhosseini, A., Laibinis, P. E., & Langer, R. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00543-x · Cited by 278
Self-citation
Metadata
- Authors
- Lahann, J., Balcells, M., Rodon, T., Lee, J., Choi, I. S., Jensen, K. F., & Langer, R.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-04-01
- Volume
- 18
- Issue
- 9
- Pages
- 3632-3638
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2005324943
- Cited by
- 172
- References
- 0
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.