Properties and Interactions of Physigrafted End-Functionalized Poly(ethylene glycol) Layers
Abstract
We have studied the properties of layers of end-functionalized poly(ethylene glycol) (PEG) grafted by one end to mica surfaces, and, using a surface force balance, the interaction between two such layers. PEG of molecular weight 3.4 kg/mol, functionalized at both ends with an N -hydroxysuccinimide carbamate (NHS) group, to form NHS−PEG−NHS, does not adsorb on mica. When a trimethylammonium group ((CH 3 ) 3 N + ) replaced one of the NHS groups to form ((CH 3 ) 3 N + )−PEG−NHS, a surface layer formed on the mica from its aqueous solution, showing that the functionalized PEG had been attached by its (CH 3 ) 3 N + end. The properties of the ((CH 3 ) 3 N + )−PEG−NHS layer were examined primarily by surface force measurements as well as by atomic force microscopy, contact angle measurements, and confocal fluorescence microscopy. The layer was found to be very smooth, and the NHS group was found to retain its reactivity also when attached to the surface, demonstrating that the end-functionalized PEG chains can be used as flexible surface-active spacers for binding amino-containing molecules to the surface. Refractive index measurements yield the adsorbance and hence mean interanchor spacing s of the PEG chains, while force profiles revealed the role of both electrostatic double layers and steric components of the normal interactions at different surface separations D . Shear forces between the sliding surfaces were first observed at compression ratios (2 L 0 / D ) ∼ 1.2, increasing markedly for (2 L 0 / D ) > 3, where L 0 is the unperturbed PEG-brush thickness. This may be attributed both to the relatively low ( L 0 / s ) ratio, which allows high interpenetration and therefore high segmental density and viscous shear dissipation between opposite layers, and to bridging effects.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Charged brushes provide considerably better lubrication up to higher compression than either neutral brushes (in organic or aqueous media) or adsorbed polyelectrolytes.
“As indicated by the different data symbols and the cartoons in Fig. 9, the charged brushes provide considerably better lubrication up to higher compression than either neutral brushes -whether in organic or in aqueous media [75, 76] -or than adsorbed polyelectrolytes [77, 78].”
From Hydration lubrication (2013) · cites this paper as [76]
Neutral brushes in aqueous media, such as PEO, provide quite weak lubrication.
“We note that neutral brushes in aqueous media, such as brushes consisting of poly(ethylene oxide), also provide quite weak lubrication [75, 76].”
From Hydration lubrication (2013) · cites this paper as [76]
The lower hydration of polar groups would also explain why PEO brushes in water provide only very moderate lubrication.
“It would also readily explain why PEO brushes in water [75, 76] provide only very moderate lubrication.”
From Hydration lubrication (2013) · cites this paper as [76]
The citation lists haven’t been fetched yet
References 57 · Cited by 102
- Authors
- Raviv, U., Frey, J., Sak, R., Laurat, P., Tadmor, R., & Klein, J.
- Affiliations
- University of Oxford (GB)
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-08-13
- Volume
- 18
- Issue
- 20
- Pages
- 7482-7495
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1985337893
- Cited by
- 102
- References
- 57
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 2 · 2019: 2 · 2018: 5 · 2017: 2 · 2016: 2 · 2015: 5 · 2014: 8 · 2013: 6 · 2012: 5
- FWCI
- 3.56
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Langmuir (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Electrostatics and Colloid Interactions
- Keywords
- mica surface, layer interaction, surface adsorption, electric double layer, steric interactions, shear force, interlayer spacing, refractive index, surface force balance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review