Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Thermoresponsive Surface-Grafted Poly(N−isopropylacrylamide) Copolymers: Effect of Phase Transitions on Protein and Bacterial Attachment

Cunliffe, David, de las Heras Alarcón, Carolina, Peters, Vanessa, Smith, James R., Alexander, Cameron·2003·Langmuir

Abstract

The ability of polymers displaying lower critical solution temperatures (LCSTs) to mediate bioadsorptive processes was assessed. Three carboxyl-terminated polymers P1 − 3 with LCSTs respectively of 20, 32, and 42 °C were prepared by free-radical polymerization of N -isopropylacrylamide with and without comonomers acrylamide and N - tert -butylacrylamide. The polymers were grafted to amine-functionalized glass substrates, and their surface properties were investigated by contact angle goniometry and atomic force microscopy. Increases in water contact angle of up to 24° were observed between 10 and 37 °C for polymers with LCSTs of 20 and 32 °C, whereas no change was apparent for control amine-functional and the LCST 42 °C polymer surfaces over this temperature range. Variations in topography in water were also apparent from atomic force microscopy (AFM) studies for all the polymer grafts but not the amine surfaces over these temperatures. Adsorption of 3 H-labeled bovine serum albumin and cytochrome c also increased to polymer grafts above the LCST, with the greatest change in the amount of attached protein being exhibited by polymer P1 (1.13 pmol·cm - 2 cytochrome c at 10 °C, 3.95 pmol·cm - 2 at 37 °C): adsorption to control surfaces varied by less than 10% in this assay. Incubation of the graft and control substrates with a gram negative and motile bacterium ( Salmonella typhimurium ) and gram positive, nonmotile species ( Bacillus cereus ) showed the same overall pattern of attachment as the protein adsorption experiments, with polymers P1 and P2 retaining more bacteria (increases of up to 1350%) at 37 °C than at temperatures below their LCST, while amine-functional and P3 polymer surfaces showed less than 20% changes in the number of attached microorganisms. Further incubations at temperatures below polymer LCST resulted in fewer adsorbed cells at the surfaces showing the reversibility of short-term attachment to these materials. The results show that protein adsorption and short-term bacterial attachment correlate well with observed changes in surface properties as determined by contact angle goniometry and indicate that control of bioadhesion is possible by grafting suitably functionalized polymers capable of temperature-mediated hydrophilic−hydrophobic switching.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la026358l

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 222

Metadata

Authors
Cunliffe, D., de las Heras Alarcón, C., Peters, V., Smith, J. R., & Alexander, C.
Venue
Langmuir
Published
2003-02-19
Volume
19
Issue
7
Pages
2888-2899
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2046826551
Cited by
222
References
2
FWCI
6.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.