Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Interaction of Water with Self-Assembled Monolayers: Neutron Reflectivity Measurements of the Water Density in the Interface Region

Schwendel, D., Hayashi, T., Dahint, R., Pertsin, A., Grunze, M., Steitz, R., Schreiber, F.·2003·Langmuir

Abstract

We applied neutron reflectivity measurements to hydrophilic and hydrophobic self-assembled monolayers (SAMs) to probe water density at these interfaces. The measurements were motivated by a previous theoretical study which reported a reduced water density at a hydrophobic surface (Lum, K.; Chandler, D.; Weeks, J. D. J. Phy s. Chem. B 1999, 103, 4570) and by our own computer simulations on the hydration force and water density between two methoxy tri(ethylene glycol) terminated undecylthiolate SAMs adsorbed on gold substrates used to study protein adsorption. These simulations predicted that the surfaces are slightly hydrophobic and are characterized by a reduced water density at the interface (Pertsin, A. J.; Hayashi, T.; Grunze, M. J. Phys. Chem. B 2002, 106, 12274). In disagreement with the marginal reduction in water density derived in the simulations, the neutron reflectivity measurements reported here indicate an unexpectedly extended (∼4 nm) water layer at the SAM surface with a noticeably reduced density (85−90% of the density of bulk water). The reproducibility of the experimental results with the methoxy tri(ethylene glycol) terminated undecylthiolate SAMs was confirmed with four different samples and by one measurement using a contrast-matched D 2 O/H 2 O water mixture. We also used neutron reflectivity measurements to study the water density at the water/SAM interface of hydroxy hexa(ethylene glycol) and hydroxy tri(ethylene glycol) terminated undecylthiolate SAMs. Except for one of the hydroxy hexa(ethylene glycol) samples studied, the results are consistent with the presence of bulk water in direct contact with the interface. We also discuss possible artifacts and problems in the analysis. Our results on nonfunctionalized hydrophobic octadecanethiolate and hydrophilic hydroxy-terminated undecylthiolate SAMs give physically unreasonable and nonconclusive models for the water interface on these surfaces, respectively. The best fit of the data for the hydrophobic surface gives an unreasonably low water density, possibly due to the presence of air inclusions in the film and/or adsorbed air “nanobubbles”. The results obtained on the hydrophilic hydroxy-terminated surface can be fitted equally well with a model assuming an interface water density that is higher or lower than that of bulk water, demonstrating the ambiguities associated with describing the organic/liquid interface with a box model for the Q range accessible in our experiment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la026716k

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 238

Metadata

Authors
Schwendel, D., Hayashi, T., Dahint, R., Pertsin, A., Grunze, M., Steitz, R., & Schreiber, F.
Venue
Langmuir
Published
2003-02-22
Volume
19
Issue
6
Pages
2284-2293
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2060444602
Cited by
238
References
2
FWCI
13.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.