The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Covalent Attachment of Poly(ethylene glycol) to Surfaces, Critical for Reducing Bacterial Adhesion
Abstract
The effects of different poly(ethylene glycol) (PEG) attachment strategies upon the adhesion of a Gram-negative bacteria ( Pseudomonas sp.) was tested. PEG was covalently immobilized, at the lower critical solution temperature of PEG, to a layer of branched poly(ethylenimine) (PEI). PEI was both physically adsorbed to a stainless-steel (SS) substrate and covalently immobilized to a carboxylated poly(ethylene terephthalate) (PET−COOH) surface. On both substrates, the PEI and PEG grafting conditions were optimized so that the levels of surface coverage after each step were maximized and were the same on both substrates, as judged by X-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Also, ToF-SIMS imaging showed that both substrates were chemically uniform after each surface modification step. Thus, the two surfaces differ only in the mode of attachment of PEI to the substrate. In bacterial adhesion experiments, the optimal SS−PEG surface was not capable of reducing the number of adherent Pseudomonas sp. when compared to the controls. However, the PET−PEG surface reduced the level of adhesion by between 2 and 4 orders of magnitude for up to 5 h. ToF-SIMS analysis showed that both PEG surfaces adsorbed low but comparable levels of proteinaceous growth medium components (tryptic soy broth), as indicated by the addition of unique amino acid fragment ions in the spectra, most likely small peptides. Thus, bacterial adhesion was strongly dependent on the PEG immobilization strategy and not on the extent of peptide/protein adsorption. However, for the best PEG surfaces the residual bacterial adhesion is most likely from recognition of the small amount of adsorbed peptides. This highlights the necessity for preventing the adsorption of small biological species that can even penetrate PEG layers of high graft density, in the quest for the ultimate “nonfouling” surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bacterial Biofilms: A Common Cause of Persistent Infections
Costerton, J. W., Stewart, P. S., & Greenberg, E. P. (1999) · Science · doi:10.1126/science.284.5418.1318 · Cited by 12,167
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Polymer surface modification for the attachment of bioactive compounds
Goddard, J. M., & Hotchkiss, J. H. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.04.002 · Cited by 1,379
Reducing implant-related infections: active release strategies
Hetrick, E. M., & Schoenfisch, M. H. (2006) · Chemical Society Reviews · doi:10.1039/b515219b · Cited by 1,201
A Switchable Biocompatible Polymer Surface with Self‐Sterilizing and Nonfouling Capabilities
Cheng, G., Xue, H., Zhang, Z., Chen, S., & Jiang, S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803570 · Cited by 371
Contact Lens Materials: A Materials Science Perspective
Musgrave, C. S. A., & Fang, F. (2019) · Materials · doi:10.3390/ma12020261 · Cited by 355
Metadata
- Authors
- Kingshott, P., Wei, J., Bagge-Ravn, D., Gadegaard, N., & Gram, L.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-07-23
- Volume
- 19
- Issue
- 17
- Pages
- 6912-6921
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2018267895
- Cited by
- 369
- References
- 1
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.