The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cast Thin Film Biosensor Design Based on a Nafion Backbone, a Multiwalled Carbon Nanotube Conduit, and a Glucose Oxidase Function
Abstract
Novel electroanalytical sensing nanobiocomposite materials are reported. These materials are prepared by mixing multiwalled carbon nanotubes (MWNTs), a Nafion cation exchanger, and glucose oxidase (GOD) in appropriate amounts. The MWNTs are cylindrical with a diameter in the range 40-60 nm and with a length of up to several micrometers, and they provide electrical conductivity. Nafion acts as a polymer backbone to give stable and homogeneous cast thin films. Both MWNTs and Nafion provide negative functionalities to bind to positively charged redox enzymes such as glucose oxidase. The resulting biosensing composite material is inexpensive, reliable, and easy to use. The homogeneity of the MWNT-Nafion-GOD nanobiocomposite films was characterized by atomic force microscopy (AFM). Amperometric transducers fabricated with these materials were characterized electrochemically using cyclic voltammetry and amperometry in the presence of hydrogen peroxide and in the presence of glucose. Their linear response to hydrogen peroxide was demonstrated. The glucose biosensor sensitivity was strongly influenced by the glucose oxidase concentration within the nanobiocomposite film. The optimized glucose biosensor (2.5 mg/mL GOD) displayed a sensitivity of 330 nA/mM, a linear range of up to 2 mM, a detection limit of 4 microM, and a response time of <3 s.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme-coated carbon nanotubes as single-molecule biosensors
Besteman, K., Lee, J.-O., Wiertz, F. G. M., Heering, H. A., & Dekker, C. (2003) · Nano Letters · doi:10.1021/nl034139u · Cited by 1,294
Cited by
Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on Graphene
Shan, C., Yang, H., Song, J., Han, D., Ivaska, A., & Niu, L. (2009) · Analytical Chemistry · doi:10.1021/ac802193c · Cited by 1,315
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Carbon nanotubes for electrochemical biosensing
RIVAS, G., RUBIANES, M., RODRIGUEZ, M., FERREYRA, N., LUQUE, G., PEDANO, M., MISCORIA, S., & PARRADO, C. (2007) · Talanta · doi:10.1016/j.talanta.2007.10.013 · Cited by 554
Lu, J., Do, I., Drzal, L. T., Worden, R. M., & Lee, I. (2008) · ACS Nano · doi:10.1021/nn800244k · Cited by 438
Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite
Chen, J., Zhang, W.-D., & Ye, J.-S. (2008) · Electrochemistry Communications · doi:10.1016/j.elecom.2008.06.022 · Cited by 408
Self-citation
Metadata
- Authors
- Tsai, Y.-C., Li, S.-C., & Chen, J.-M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-03-09
- Volume
- 21
- Issue
- 8
- Pages
- 3653-3658
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2064878932
- Cited by
- 223
- References
- 1
- FWCI
- 21.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cast Thin Film Biosensor Design Based on a Nafion Backbone, a Multiwalled Carbon Nanotube Conduit, and a Glucose Oxidase Function. https://app.cochat.ai/papers/10.1021/la0470535
- The paper
- Tsai, Y.-C., Li, S.-C., & Chen, J.-M. (2005). Cast Thin Film Biosensor Design Based on a Nafion Backbone, a Multiwalled Carbon Nanotube Conduit, and a Glucose Oxidase Function. Langmuir. https://doi.org/10.1021/la0470535
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.