The DOI matches its Crossref record.
Controlled Synthesis of Nonspherical Microparticles Using Microfluidics
Abstract
The controlled synthesis of nonspherical microparticles using microfluidics processing is described. Polymer droplets, formed by shearing a photopolymer using a continuous water phase at a T-junction, were constrained to adopt nonspherical shapes by confining them using appropriate microchannel geometries. Plugs were obtained by shearing the polymer phase at low shear rates, while disks were obtained by flattening droplets using a channel of low height. The nonspherical shapes formed were permanently preserved by photopolymerizing the constrained droplets in situ using ultraviolet light. Monodisperse plugs and disks of different lengths and diameters were obtained by varying the flow rates of the two phases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Teh, S.-Y., Lin, R., Hung, L.-H., & Lee, A. P. (2008) · Lab on a Chip · doi:10.1039/b715524g · Cited by 2,690
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Particle shape: A new design parameter for micro- and nanoscale drug delivery carriers
Champion, J. A., Katare, Y. K., & Mitragotri, S. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.03.022 · Cited by 1,206
Multiphase microfluidics: from flow characteristics to chemical and materials synthesis
Günther, A., & Jensen, K. F. (2006) · Lab Chip · doi:10.1039/b609851g · Cited by 983
Metadata
- Authors
- Dendukuri, D., Tsoi, K., Hatton, T. A., & Doyle, P. S.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-02-11
- Volume
- 21
- Issue
- 6
- Pages
- 2113-2116
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2019646543
- Cited by
- 482
- References
- 0
- FWCI
- 22.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controlled Synthesis of Nonspherical Microparticles Using Microfluidics. https://app.cochat.ai/papers/10.1021/la047368k
- The paper
- Dendukuri, D., Tsoi, K., Hatton, T. A., & Doyle, P. S. (2005). Controlled Synthesis of Nonspherical Microparticles Using Microfluidics. Langmuir. https://doi.org/10.1021/la047368k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.