Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 660

The DOI matches its Crossref record.

Analysis of the Microfluid Flow in an Evaporating Sessile Droplet

Hu, Hua, Larson, Ronald G.·2005·Langmuir

Abstract

The axisymmetric time-dependent flow field in an evaporating sessile droplet whose contact line is pinned is studied numerically and using an analytical lubrication theory with a zero-shear-stress boundary condition on the free surface of the droplet at low capillary and Reynolds numbers. A finite element algorithm is developed to solve simultaneously the vapor concentration and flow field in the droplet under conditions of slow evaporation. The finite element solution confirms the accuracy of the lubrication solution, especially when terms of higher order in the droplet flatness ratio (the ratio of droplet height to radius, h/R) are included in the lubrication theory to account more accurately for the singular flow near the contact line.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la047528s

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 660

Metadata

Authors
Hu, H., & Larson, R. G.
Venue
Langmuir
Published
2005-03-26
Volume
21
Issue
9
Pages
3963-3971
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W1980219728
Cited by
660
References
0
FWCI
21.25
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Analysis of the Microfluid Flow in an Evaporating Sessile Droplet. https://app.cochat.ai/papers/10.1021/la047528s
The paper
Hu, H., & Larson, R. G. (2005). Analysis of the Microfluid Flow in an Evaporating Sessile Droplet. Langmuir. https://doi.org/10.1021/la047528s

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.