The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Microbial Adhesion to Poly(ethylene oxide) Brushes: Influence of Polymer Chain Length and Temperature
Open accessAbstract
Glass surfaces were modified by end-grafting poly(ethylene oxide) (PEO) chains having molecular weights of 526, 2000, or 9800 Da. Characterization using water contact angles, ellipsometry, and X-ray photoelectron spectroscopy confirmed the presence of the PEO brushes on the surface with estimated lengths in water of 2.8-, 7.5-, and 23.7-nm, respectively. Adhesion of two bacterial (Staphylococcus epidermidis and Pseudomonas aeruginosa) and two yeast (Candida albicans and Candida tropicalis) strains to these brushes was studied and compared to their adhesion to bare glass. For the bacterium P. aeruginosa and the yeast C. tropicalis, adhesion to the 2.8-nm brush was comparable to their adhesion on bare glass, whereas adhesion to the 7.5- and 23.7-nm brushes was greatly reduced. For S. epidermidis, adhesion was only slightly higher to the 2.8-nm brush than that to the longer brushes. Adhesion of the yeast C. albicans to the PEO brushes was lower than that to glass, but no differences in adhesion were found between the three brush lengths. After passage of an air bubble, nearly all microorganisms adhering to a brush were removed, irrespective of brush length, whereas retention of the adhering organisms on glass was much higher. No significant differences were found in adhesion nor retention between experiments conducted at 20 and those conducted at 37 degrees C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A reference guide to microbial cell surface hydrophobicity based on contact angles
van der Mei, H. C., Bos, R., & Busscher, H. J. (1998) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(98)00037-x · Cited by 253
Self-citation
Cited by
Banerjee, I., Pangule, R. C., & Kane, R. S. (2011) · Advanced Materials · doi:10.1002/adma.201001215 · Cited by 2,749
Novel Strategies for the Prevention and Treatment of Biofilm Related Infections
Chen, M., Yu, Q., & Sun, H. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918488 · Cited by 429
A Switchable Biocompatible Polymer Surface with Self‐Sterilizing and Nonfouling Capabilities
Cheng, G., Xue, H., Zhang, Z., Chen, S., & Jiang, S. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200803570 · Cited by 371
Antimicrobial Copper-Based Materials and Coatings: Potential Multifaceted Biomedical Applications
Mitra, D., Kang, E.-T., & Neoh, K. G. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b17815 · Cited by 322
Yang, Y.-F., Li, Y., Li, Q.-L., Wan, L.-S., & Xu, Z.-K. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.06.048 · Cited by 289
Metadata
- Authors
- Roosjen, A., van der Mei, H. C., Busscher, H. J., & Norde, W.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-11-02
- Volume
- 20
- Issue
- 25
- Pages
- 10949-10955
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2094749176
- Cited by
- 247
- References
- 1
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbial Adhesion to Poly(ethylene oxide) Brushes: Influence of Polymer Chain Length and Temperature. https://app.cochat.ai/papers/10.1021/la048469l
- The paper
- Roosjen, A., van der Mei, H. C., Busscher, H. J., & Norde, W. (2004). Microbial Adhesion to Poly(ethylene oxide) Brushes: Influence of Polymer Chain Length and Temperature. Langmuir. https://doi.org/10.1021/la048469l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.