Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 238

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electrochemical Deposition of Silver in Room-Temperature Ionic Liquids and Its Surface-Enhanced Raman Scattering Effect

He, Ping, Liu, Hongtao, Li, Zhiying, Liu, Yang, Xu, Xiudong, Li, Jinghong·2004·Langmuir

Abstract

The use of room-temperature ionic liquids (RTILs) as media for electrochemical application is very attractive. In this work, the electrochemical deposition of silver was investigated at a glassy carbon electrode in hydrophobic 1-n-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6) and hydrophilic 1-n-butyl-3-methylimidazolium tetrafluoroborate (BMIMBF4) RTILs and in KNO3 aqueous solution by cyclic voltammetric and potentiostatic transient techniques. The voltammograms showed the presence of reduction and oxidation peaks associated with the deposition and dissolution of silver from AgBF4 in both BMIMPF6 and BMIMBF(4), resembling the redox behavior of AgNO3 in KNO3 aqueous solution. A crossover loop was observed in all the cyclic voltammograms of these electrochemical systems, indicating a nucleation process. From the analysis of the experimental current transients, it was shown that the electrochemical deposition process of silver in these media was characteristic of 3D nucleation with diffusion-controlled hemispherical growth, and the silver nucleation closely followed the response predicted for progressive nucleation in BMIMPF6 and instantaneous nucleation in KNO3 aqueous solution, respectively. Compared with these two cases, the electrochemical deposition of silver in BMIMBF4 deviated from both the instantaneous and progressive nucleation models, which could be controlled by mixed kinetics and diffusion. On the basis of the experimental results, it was shown that parameters such as viscosity and water miscibility of RTILs would affect the electrodeposition behavior of silver. Atom force microscopy was employed to probe the surface morphology of the silver deposit, and it showed that the shining electrodeposit of silver was fairly dense and separate nanoclusters of <100 nm were in evidence, corresponding to an island growth model. The strongly enhanced Raman scattering from the monolayer film of 4-mercaptobenzoic acid demonstrated that as-prepared silver nanoparticular film was surface-enhanced Raman scattering (SERS) active. The enhancement factor was calculated to be up to 9.0 x 10(5) and 1.0 x 10(6) for the silver film obtained in BMIMPF6 and BMIMBF4 RTILs, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la048480l

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 238

Metadata

Authors
He, P., Liu, H., Li, Z., Liu, Y., Xu, X., & Li, J.
Venue
Langmuir
Published
2004-10-15
Volume
20
Issue
23
Pages
10260-10267
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W1973010780
Cited by
238
References
1
FWCI
14.71
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrochemical Deposition of Silver in Room-Temperature Ionic Liquids and Its Surface-Enhanced Raman Scattering Effect. https://app.cochat.ai/papers/10.1021/la048480l
The paper
He, P., Liu, H., Li, Z., Liu, Y., Xu, X., & Li, J. (2004). Electrochemical Deposition of Silver in Room-Temperature Ionic Liquids and Its Surface-Enhanced Raman Scattering Effect. Langmuir. https://doi.org/10.1021/la048480l

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.