The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane)
Abstract
This paper describes the influence of the composition of poly(dimethylsiloxane) (PDMS) on the attachment and growth of several different types of mammalian cells: primary human umbilical artery endothelial cells (HUAECs), transformed 3T3 fibroblasts (3T3s), transformed osteoblast-like MC3T3-E1 cells, and HeLa (transformed epithelial) cells. Cells grew on PDMS having different ratios of base to curing agent: 10:1 (normal PDMS, PDMSN), 10:3 (PDMSCA), and 10:0.5 (PDMSB). They were also grown on "extracted PDMS" (normal PDMS that has reduced quantities of low molecular-weight oligomers, PDMSN,EX) and normal PDMS that had been extracted and then oxidized (PDMSN,EX,OX); all surfaces were exposed to a solution of fibronectin prior to cell attachment. Generally, fibronectin-coated PDMS is a suitable substrate for culturing mammalian cells. Compatibility of cells on some surfaces, however, was dependent on the cell type: PDMSN,EX,OX caused cell detachment of 3T3 fibroblasts and MC3T3-E1 cells, and PDMSCA caused detachment of HUAECs and HeLa cells. Growth of cells on PDMSN, PDMSN,EX, and PDMSB was comparable to growth on tissue culture-treated polystyrene for most of the cell types. All cells grew at similar rates on PDMS substrates regardless of the stiffness of the substrate, for substrates having Young's moduli ranging from E=0.60 +/- 0.04 to 2.6 +/- 0.2 MPa (for PDMSB and PDMSN,EX, respectively).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Self-citationPoly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Self-citationMicrofluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Young, R. J., & Lovell, P. A. (1992) · Springer eBooks · doi:10.1007/978-1-4615-3478-5 · Cited by 2,116
Mrksich, M., & Whitesides, G. M. (1996) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.25.060196.000415 · Cited by 850
Self-citationEffect of Surface Wettability on the Adsorption of Proteins and Detergents
Sigal, G. B., Mrksich, M., & Whitesides, G. M. (1998) · Journal of the American Chemical Society · doi:10.1021/ja970819l · Cited by 816
Self-citationPhysical ceramics: principles for ceramic science and engineering
(1996) · Choice Reviews Online · doi:10.5860/choice.34-1566 · Cited by 721
Garcı́a, A. J., Vega, M. D., & Boettiger, D. (1999) · Molecular Biology of the Cell · doi:10.1091/mbc.10.3.785 · Cited by 659
Grinnell, F., & Feld, M. K. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34609-x · Cited by 622
Cited by
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Self-citationMicrofluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Substrate stiffness affects early differentiation events in embryonic stem cells
Dept Materials, R. S. O. M., Evans, N., Minelli, C., Gentleman, E., LaPointe, V, Patankar, S., Kallivretaki, M., Chen, X., Roberts, C., & Stevens, M. (2009) · European Cells and Materials · doi:10.22203/ecm.v018a01 · Cited by 466
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Metadata
- Authors
- Lee, J. N., Jiang, X., Ryan, D., & Whitesides, G. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-11-19
- Volume
- 20
- Issue
- 26
- Pages
- 11684-11691
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2099423350
- Cited by
- 379
- References
- 32
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane). https://app.cochat.ai/papers/10.1021/la048562+
- The paper
- Lee, J. N., Jiang, X., Ryan, D., & Whitesides, G. M. (2004). Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane). Langmuir. https://doi.org/10.1021/la048562%2B
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.