The DOI matches its Crossref record.
Multilayered Thin Films that Sustain the Release of Functional DNA under Physiological Conditions
Abstract
The development of thin films and coatings that control the release of DNA from the surfaces of materials could have a significant impact on localized approaches to gene therapy. Here, we report multilayered polyelectrolyte assemblies that sustain the release of functional plasmid DNA from the surfaces of model substrates under physiological conditions. Multilayered assemblies consisting of alternating layers of plasmid DNA encoding for enhanced green fluorescent protein (EGFP) and a synthetic degradable polyamine were deposited on planar silicon and quartz substrates using a layer-by-layer fabrication process. Film growth was monitored by ellipsometry and UV spectrophotometry and correlated linearly with the number of polymer and plasmid layers deposited. In general, the thickness of deposited layers was found to be a function of both the pH and the ionic strength of the polyelectrolyte solutions used. Films up to 100 nm thick were investigated in this study. These assemblies erode gradually upon incubation in phosphate-buffered saline at 37 degrees C, as determined by ellipsometry and UV spectrophotometry, and sustain the release of incorporated plasmid into the incubation medium for a period of up to 30 h. Characterization of the released plasmid by agarose gel electrophoresis revealed that the DNA was released in a relaxed, open circular, rather than supercoiled, topology; subsequent cell transfection experiments demonstrated that the released plasmid is transcriptionally viable and promotes the expression of EGFP in the COS-7 cell line. These layered materials could represent an approach to the controlled administration of one or more functional DNA constructs from the surfaces of biomedical materials and devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biomedical Applications of Layer‐by‐Layer Assembly: From Biomimetics to Tissue Engineering
Tang, Z., Wang, Y., Podsiadlo, P., & Kotov, N. A. (2006) · Advanced Materials · doi:10.1002/adma.200600113 · Cited by 1,302
Ariga, K., Hill, J. P., & Ji, Q. (2007) · Physical Chemistry Chemical Physics · doi:10.1039/b700410a · Cited by 1,256
Challenges and breakthroughs in recent research on self-assembly
Ariga, K., Hill, J. P., Lee, M. V., Vinu, A., Charvet, R., & Acharya, S. (2008) · Science and Technology of Advanced Materials · doi:10.1088/1468-6996/9/1/014109 · Cited by 759
Polymers for gene delivery across length scales
Putnam, D. (2006) · Nature Materials · doi:10.1038/nmat1645 · Cited by 572
Release mechanisms for polyelectrolyte capsules
De Geest, B. G., Sanders, N. N., Sukhorukov, G. B., Demeester, J., & De Smedt, S. C. (2007) · Chem. Soc. Rev. · doi:10.1039/b600460c · Cited by 462
Polymer systems for gene delivery—Past, present, and future
Wong, S. Y., Pelet, J. M., & Putnam, D. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.007 · Cited by 427
Polymeric Delivery of Therapeutic Nucleic Acids
Kumar, R., Santa Chalarca, C. F., Bockman, M. R., Bruggen, C. V., Grimme, C. J., Dalal, R. J., Hanson, M. G., Hexum, J. K., & Reineke, T. M. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00997 · Cited by 365
JEWELL, C., & LYNN, D. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.02.010 · Cited by 297
Self-citationDrug Releasing Polymer Thin Films: New Era of Surface-Mediated Drug Delivery
Zelikin, A. N. (2010) · ACS Nano · doi:10.1021/nn100634r · Cited by 289
Polyelectrolyte microcapsules for biomedical applications
De Geest, B. G., De Koker, S., Sukhorukov, G. B., Kreft, O., Parak, W. J., Skirtach, A. G., Demeester, J., De Smedt, S. C., & Hennink, W. E. (2009) · Soft Matter · doi:10.1039/b808262f · Cited by 289
Wood, K. C., Chuang, H. F., Batten, R. D., Lynn, D. M., & Hammond, P. T. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602884103 · Cited by 270
Self-citationAdvanced in developmental organic and inorganic nanomaterial: a review
Khalid, K., Tan, X., Mohd Zaid, H. F., Tao, Y., Lye Chew, C., Chu, D.-T., Lam, M. K., Ho, Y.-C., Lim, J. W., & Chin Wei, L. (2020) · Bioengineered · doi:10.1080/21655979.2020.1736240 · Cited by 263
Matrices and scaffolds for DNA delivery in tissue engineering
De Laporte, L., & Shea, L. D. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.03.017 · Cited by 258
Facile DNA immobilization on surfaces through a catecholamine polymer
Ham, H. O., Liu, Z., Lau, K. H. A., Lee, H., & Messersmith, P. B. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201005001 · Cited by 189
Combining Topographical and Genetic Cues to Promote Neuronal Fate Specification in Stem Cells
Purcell, E. K., Naim, Y., Yang, A., Leach, M. K., Velkey, J. M., Duncan, R. K., & Corey, J. M. (2012) · Biomacromolecules · doi:10.1021/bm301220k · Cited by 26
Metadata
- Authors
- Zhang, J., Chua, L. S., & Lynn, D. M.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-07-31
- Volume
- 20
- Issue
- 19
- Pages
- 8015-8021
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2006551547
- Cited by
- 248
- References
- 0
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.