The DOI matches its Crossref record.
Fluorescence-Modified Superparamagnetic Nanoparticles: Intracellular Uptake and Use in Cellular Imaging
Abstract
This report describes the preparation and characterization of new magnetic fluorescent nanoparticles and our success in using them to label living cells. The bifunctional nanoparticles possess a magnetic oxide core composed of a dimercaptosuccinic acid (DMSA) ligand at the surface and a covalently attached fluorescent dye. The nanoparticles exhibited a high affinity for cells, which was demonstrated by fluorescence microscopy and magnetophoresis. Fluorescence microscopy was used to monitor the localization patterns of magnetic nanoparticles associated with cells. We observed two types of magnetic labeling: adsorption of the nanoparticles on the cell membrane (membranous fluorescence) and internalization of the nanoparticles inside the cell (intracellular vesicular fluorescence). After internalization, nanoparticles were confined inside endosomes, which are submicrometric vesicles of the endocytotic pathway. We demonstrated that endosome movement could be piloted inside the cell by external magnetic fields such that small fluorescent chains of magnetic endosomes were formed in the cell cytoplasm in the direction of the applied magnetic field. Finally, by measuring the critical cellular magnetic load (quantitated by magnetophoresis), we have demonstrated the potential of this new magneto-fluorescent nanoagent for medical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yantasee, W., Warner, C. L., Sangvanich, T., Addleman, R. S., Carter, T. G., Wiacek, R. J., Fryxell, G. E., Timchalk, C., & Warner, M. G. (2007) · Environmental Science & Technology · doi:10.1021/es0705238 · Cited by 688
Figuerola, A., Di Corato, R., Manna, L., & Pellegrino, T. (2010) · Pharmacological Research · doi:10.1016/j.phrs.2009.12.012 · Cited by 480
Oh, J. K., & Park, J. M. (2011) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2010.08.005 · Cited by 427
Villanueva, A., Cañete, M., Roca, A. G., Calero, M., Veintemillas-Verdaguer, S., Serna, C. J., del Puerto Morales, M., & Miranda, R. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/11/115103 · Cited by 299
Engineered nanoparticles for biomolecular imaging
Mahmoudi, M., Serpooshan, V., & Laurent, S. (2011) · Nanoscale · doi:10.1039/c1nr10326a · Cited by 262
Metadata
- Authors
- Bertorelle, F., Wilhelm, C., Roger, J., Gazeau, F., Ménager, C., & Cabuil, V.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-05-11
- Volume
- 22
- Issue
- 12
- Pages
- 5385-5391
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1965375981
- Cited by
- 211
- References
- 0
- FWCI
- 12.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence-Modified Superparamagnetic Nanoparticles: Intracellular Uptake and Use in Cellular Imaging. https://app.cochat.ai/papers/10.1021/la052710u
- The paper
- Bertorelle, F., Wilhelm, C., Roger, J., Gazeau, F., Ménager, C., & Cabuil, V. (2006). Fluorescence-Modified Superparamagnetic Nanoparticles: Intracellular Uptake and Use in Cellular Imaging. Langmuir. https://doi.org/10.1021/la052710u
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.