Changes in Adsorbed Fibrinogen upon Conversion to Fibrin
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The conversion of adsorbed fibrinogen to fibrin in the presence of the enzyme thrombin was studied using surface plasmon resonance (SPR), a quartz crystal microbalance (QCM), sum frequency generation (SFG), atomic force microscopy (AFM), and an elutability assay. Exposure of adsorbed fibrinogen to thrombin resulted in a mass loss at the surface consistent with fibrinopeptide release and conversion to fibrin. Changes in hydration upon conversion of adsorbed fibrinogen to fibrin were determined from comparisons of acoustic (QCM) and optical (SPR) mass adsorption data. Conversion to fibrin also resulted in the adsorbed layer becoming more strongly bound to the surface and more compact. The elutability of adsorbed fibrinogen by Triton X-100, studied with SPR, decreased from 90 +/- 5 to 6 +/- 2% after conversion to fibrin. The height of the adsorbed monolayer, as determined by AFM, decreased from 5.5 +/- 2.2 to 1.7 +/- 0.8 nm. We conclude that thrombin-catalyzed fibrinopeptide release triggers significant changes in fibrinogen conformation beyond peptide cleavage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biological Responses to Materials
Anderson, J. M. (2001) · Annual Review of Materials Research · doi:10.1146/annurev.matsci.31.1.81 · Cited by 1,465
Cited by
Surface Chemistry Influences Implant Biocompatibility
Tang, L., Thevenot, P., & Hu, W. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790901 · Cited by 800
Macrophages, Foreign Body Giant Cells and Their Response to Implantable Biomaterials
Sheikh, Z., Brooks, P., Barzilay, O., Fine, N., & Glogauer, M. (2015) · Materials · doi:10.3390/ma8095269 · Cited by 701
“As explained previously, immediately after implantation, the biomaterial surface is covered with a layer of plasma proteins [165,166], and these proteins, possibly via hydrophobic interactions, adopt an altered conformation and to expose the hydrophobic domains which are highly adherent to hydrophobic biomaterial surf…”
BackgroundSurvey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Hosseinpour, S., Roeters, S. J., Bonn, M., Peukert, W., Woutersen, S., & Weidner, T. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00410 · Cited by 208
Metadata
- Authors
- Evans-Nguyen, K. M., Fuierer, R. R., Fitchett, B. D., Tolles, L. R., Conboy, J. C., & Schoenfisch, M. H.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-04-19
- Volume
- 22
- Issue
- 11
- Pages
- 5115-5121
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2073413303
- Cited by
- 59
- References
- 1
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.