The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Adhesion of Bioinspired Micropatterned Surfaces: Effects of Pillar Radius, Aspect Ratio, and Preload
Abstract
Inspired by biological attachment systems, micropatterned elastomeric surfaces with pillars of different heights (between 2.5 and 80 microm) and radii (between 2.5 and 25 microm) were fabricated. Their adhesion properties were systematically tested and compared with flat controls. Micropatterned surfaces with aspect ratios above 0.5 were found to be more compliant than flat surfaces. The adhesion significantly increases with decreasing pillar radius and increasing aspect ratio of the patterned features. A preload dependence of the adhesion force has been identified and demonstrated to be crucial for obtaining adhesives with tunable adherence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Cited by
Natural Bactericidal Surfaces: Mechanical Rupture of Pseudomonas aeruginosa Cells by Cicada Wings
Ivanova, E. P., Hasan, J., Webb, H. K., Truong, V. K., Watson, G. S., Watson, J. A., Baulin, V. A., Pogodin, S., Wang, J. Y., Tobin, M. J., et al. (2012) · Small · doi:10.1002/smll.201200528 · Cited by 1,019
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
Contact Shape Controls Adhesion of Bioinspired Fibrillar Surfaces
del Campo, A., Greiner, C., & Arzt, E. (2007) · Langmuir · doi:10.1021/la7010502 · Cited by 465
Self-citation
Metadata
- Authors
- Greiner, C., del Campo, A., & Arzt, E.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-22
- Volume
- 23
- Issue
- 7
- Pages
- 3495-3502
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1980635640
- Cited by
- 435
- References
- 1
- FWCI
- 40.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.