The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Emerging Techniques for Submicrometer Particle Sizing Applied to Stöber Silica
Abstract
The accurate characterization of submicrometer and nanometer sized particles presents a major challenge in the diverse applications envisaged for them including cosmetics, biosensors, renewable energy, and electronics. Size is one of the principal parameters for classifying particles and understanding their behavior, with other particle characteristics usually only quantifiable when size is accounted for. We present a comparative study of emerging and established techniques to size submicrometer particles, evaluating their sizing precision and relative resolution, and demonstrating the variety of physical principles upon which they are based, with the aim of developing a framework in which they can be compared. We used in-house synthesized Stöber silica particles between 100 and 400 nm in diameter as reference materials for this study. The emerging techniques of scanning ion occlusion sensing (SIOS), differential centrifugal sedimentation (DCS), and nanoparticle tracking analysis (NTA) were compared to the established techniques of transmission electron microscopy (TEM), scanning mobility particle sizing (SMPS), and dynamic light scattering (DLS). The size distributions were described using the mode, arithmetic mean, and standard deviation. Uncertainties associated with the six techniques were evaluated, including the statistical uncertainties in the mean sizes measured by the single-particle counting techniques. Q-Q plots were used to analyze the shapes of the size distributions. Through the use of complementary techniques for particle sizing, a more complete characterization of the particles was achieved, with additional information on their density and porosity attained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mesoporous silica nanoparticles for drug delivery and biosensing applications
Slowing, I. I., Trewyn, B. G., Giri, S., & Lin, V. S. ‐. (2007) · Advanced Functional Materials · doi:10.1002/adfm.200601191 · Cited by 1,699
Nanoparticle Technology for Drug Delivery Across the Blood-Brain Barrier
Lockman, P. R., Mumper, R. J., Khan, M. A., & Allen, D. D. (2002) · Drug Development and Industrial Pharmacy · doi:10.1081/ddc-120001481 · Cited by 592
Cytotoxicity and oxidative stress induced by different metallic nanoparticles on human kidney cells
Pujalté, I., Passagne, I., Brouillaud, B., Tréguer, M., Durand, E., Ohayon-Courtès, C., & L'Azou, B. (2011) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-8-10 · Cited by 398
Cited by
Mourdikoudis, S., Pallares, R. M., & Thanh, N. T. K. (2018) · Nanoscale · doi:10.1039/c8nr02278j · Cited by 2,191
Anderson, W., Kozak, D., Coleman, V. A., Jämting, Å. K., & Trau, M. (2013) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2013.02.030 · Cited by 373
Michen, B., Geers, C., Vanhecke, D., Endes, C., Rothen-Rutishauser, B., Balog, S., & Petri-Fink, A. (2015) · Scientific Reports · doi:10.1038/srep09793 · Cited by 289
Maas, S. L. N., de Vrij, J., van der Vlist, E. J., Geragousian, B., van Bloois, L., Mastrobattista, E., Schiffelers, R. M., Wauben, M. H. M., Broekman, M. L. D., & Nolte-'t Hoen, E. N. M. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.12.041 · Cited by 285
Metadata
- Authors
- Bell, N. C., Minelli, C., Tompkins, J., Stevens, M. M., & Shard, A. G.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-11
- Volume
- 28
- Issue
- 29
- Pages
- 10860-10872
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2320295428
- Cited by
- 168
- References
- 3
- FWCI
- 18.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Emerging Techniques for Submicrometer Particle Sizing Applied to Stöber Silica. https://app.cochat.ai/papers/10.1021/la301351k
- The paper
- Bell, N. C., Minelli, C., Tompkins, J., Stevens, M. M., & Shard, A. G. (2012). Emerging Techniques for Submicrometer Particle Sizing Applied to Stöber Silica. Langmuir. https://doi.org/10.1021/la301351k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.