The Electrochemical Surface Forces Apparatus: The Effect of Surface Roughness, Electrostatic Surface Potentials, and Anodic Oxide Growth on Interaction Forces, and Friction between Dissimilar Surfaces in Aqueous Solutions
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
We present a newly designed electrochemical surface forces apparatus (EC-SFA) that allows control and measurement of surface potentials and interfacial electrochemical reactions with simultaneous measurement of normal interaction forces (with nN resolution), friction forces (with μN resolution), and distances (with Å resolution) between apposing surfaces. We describe three applications of the developed EC-SFA and discuss the wide-range of potential other applications. In particular, we describe measurements of (1) force-distance profiles between smooth and rough gold surfaces and apposing self-assembled monolayer-covered smooth mica surfaces; (2) the effective changing thickness of anodically growing oxide layers with Å-accuracy on rough and smooth surfaces; and (3) friction forces evolving at a metal-ceramic contact, all as a function of the applied electrochemical potential. Interaction forces between atomically smooth surfaces are well-described using DLVO theory and the Hogg-Healy-Fuerstenau approximation for electric double layer interactions between dissimilar surfaces, which unintuitively predicts the possibility of attractive double layer forces between dissimilar surfaces whose surface potentials have similar sign, and repulsive forces between surfaces whose surface potentials have opposite sign. Surface roughness of the gold electrodes leads to an additional exponentially repulsive force in the force-distance profiles that is qualitatively well described by an extended DLVO model that includes repulsive hydration and steric forces. Comparing the measured thickness of the anodic gold oxide layer and the charge consumed for generating this layer allowed the identification of its chemical structure as a hydrated Au(OH)(3) phase formed at the gold surface at high positive potentials. The EC-SFA allows, for the first time, one to look at complex long-term transient effects of dynamic processes (e.g., relaxation times), which are also reflected in friction forces while tuning electrochemical surface potentials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carlson, C., Hussain, S. M., Schrand, A. M., K. Braydich-Stolle, L., Hess, K. L., Jones, R. L., & Schlager, J. J. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp712087m · Cited by 1,814
Israelachvili, J. N., & Adams, G. E. (1978) · Journal of the Chemical Society, Faraday Transactions 1: Physical Chemistry in Condensed Phases · doi:10.1039/f19787400975 · Cited by 1,812
Self-citationParallel cylindrical water nanochannels in Nafion fuel-cell membranes
Schmidt-Rohr, K., & Chen, Q. (2008) · Nature Materials · doi:10.1038/nmat2074 · Cited by 1,371
Coordinated protein sorting, targeting and distribution in polarized cells
Mellman, I., & Nelson, W. J. (2008) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2525 · Cited by 521
Dlvo and hydration forces between mica surfaces in Mg2+, Ca2+, Sr2+, and Ba2+ chloride solutions
Pashley, R. M., & Israelachvili, J. N. (1984) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(84)90316-3 · Cited by 453
Self-citation
Cited by
Ionic liquids behave as dilute electrolyte solutions
Gebbie, M. A., Valtiner, M., Banquy, X., Fox, E. T., Henderson, W. A., & Israelachvili, J. N. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1307871110 · Cited by 442
Self-citationHigh-density diffuse optical tomography for imaging human brain function
Wheelock, M. D., Culver, J. P., & Eggebrecht, A. T. (2019) · Review of Scientific Instruments · doi:10.1063/1.5086809 · Cited by 168
Electrotunable friction with ionic liquid lubricants
Bresme, F., Kornyshev, A. A., Perkin, S., & Urbakh, M. (2022) · Nature Materials · doi:10.1038/s41563-022-01273-7 · Cited by 105
Baimpos, T., Shrestha, B. R., Raman, S., & Valtiner, M. (2014) · Langmuir · doi:10.1021/la500288w · Cited by 94
Self-citationSurface Forces Apparatus Measurements of Interactions between Rough and Reactive Calcite Surfaces
Dziadkowiec, J., Javadi, S., Bratvold, J. E., Nilsen, O., & Røyne, A. (2018) · Langmuir · doi:10.1021/acs.langmuir.8b00797 · Cited by 52
Metadata
- Authors
- Valtiner, M., Banquy, X., Kristiansen, K., Greene, G. W., & Israelachvili, J. N.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-08-29
- Volume
- 28
- Issue
- 36
- Pages
- 13080-13093
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2035361477
- Cited by
- 137
- References
- 5
- FWCI
- 5.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Electrochemical Surface Forces Apparatus: The Effect of Surface Roughness, Electrostatic Surface Potentials, and Anodic Oxide Growth on Interaction Forces, and Friction between Dissimilar Surfaces in Aqueous Solutions. https://app.cochat.ai/papers/10.1021/la3018216
- The paper
- Valtiner, M., Banquy, X., Kristiansen, K., Greene, G. W., & Israelachvili, J. N. (2012). The Electrochemical Surface Forces Apparatus: The Effect of Surface Roughness, Electrostatic Surface Potentials, and Anodic Oxide Growth on Interaction Forces, and Friction between Dissimilar Surfaces in Aqueous Solutions. Langmuir. https://doi.org/10.1021/la3018216
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.