The DOI matches its Crossref record.
Cotton Fabrics with Single-Faced Superhydrophobicity
Abstract
This article reports on the fabrication of cotton fabrics with single-faced superhydrophobicity using a simple foam finishing process. Unlike most commonly reported superhydrophobic fabrics, the fabrics developed in this study exhibit asymmetric wettability on their two faces: one face showing superhydrophobic behavior (highly nonwetting or water-repellent characteristics) and the other face retaining the inherent hydrophilic nature of cotton. The superhydrophobic face exhibits a low contact angle hysteresis of θ(a)/θ(r) = 151°/144° (θ(a), advancing contact angle; θ(r), receding contact angle), which enables water drops to roll off the surface easily so as to endow the surface with well-known self-cleaning properties. The untreated hydrophilic face preserves its water-absorbing capability, resulting in 44% of the water-absorbing capacity compared to that of the original cotton samples with both sides untreated (hydrophilic). The single-faced superhydrophobic fabrics also retain moisture transmissibility that is as good as that of the original untreated cotton fabrics. They also show robust washing fastness with the chemical cross-linking process of hydrophobic fluoropolymer to fabric fibers. Fabric materials with such asymmetric or gradient wettability will be of great use in many applications such as unidirectional liquid transporting, moisture management, microfluidic systems, desalination of seawater, flow management in fuel cells, and water/oil separation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, B., Liang, W., Guo, Z., & Liu, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00220b · Cited by 1,574
Oil/water separation techniques: a review of recent progresses and future directions
Gupta, R. K., Dunderdale, G. J., England, M. W., & Hozumi, A. (2017) · Journal of Materials Chemistry A · doi:10.1039/c7ta02070h · Cited by 1,128
Robust superhydrophobicity: mechanisms and strategies
Zhang, W., Wang, D., Sun, Z., Song, J., & Deng, X. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00751j · Cited by 686
Li, S., Huang, J., Chen, Z., Chen, G., & Lai, Y. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta07984a · Cited by 622
Janus Membranes: Exploring Duality for Advanced Separation
Yang, H., Hou, J., Chen, V., & Xu, Z. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201601589 · Cited by 534
Superhydrophobic Surfaces Developed by Mimicking Hierarchical Surface Morphology of Lotus Leaf
Latthe, S., Terashima, C., Nakata, K., & Fujishima, A. (2014) · Molecules · doi:10.3390/molecules19044256 · Cited by 482
Novel Asymmetric Wettable AgNPs/Chitosan Wound Dressing: In Vitro and In Vivo Evaluation
Liang, D., Lu, Z., Yang, H., Gao, J., & Chen, R. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b11160 · Cited by 403
Miao, D., Huang, Z., Wang, X., Yu, J., & Ding, B. (2018) · Small · doi:10.1002/smll.201801527 · Cited by 356
Park, S.-H., Lee, S., Moreira, D., Bandaru, P. R., Han, I., & Yun, D.-J. (2015) · Scientific Reports · doi:10.1038/srep15430 · Cited by 40
Metadata
- Authors
- Liu, Y., Xin, J. H., & Choi, C.-H.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-12-05
- Volume
- 28
- Issue
- 50
- Pages
- 17426-17434
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2329414359
- Cited by
- 168
- References
- 0
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.