Margination Propensity of Vascular-Targeted Spheres from Blood Flow in a Microfluidic Model of Human Microvessels
The DOI matches its Crossref record.
Abstract
Many variants of vascular-targeted carriers (VTCs) have been investigated for therapeutic intervention in several human diseases. However, in order to optimize the functionality of VTC in vivo, carriers' physical properties, such as size and shape, are important considerations for a VTC design that evades the reticuloendothelial system (RES) and successfully interacts with the targeted vessel wall. Nonetheless, little evidence has been presented on the role of size in VTC's interactions with the vascular wall, particularly in the microcirculation. Thus, in this work, we explore how particle size, along with hemodynamics (blood shear rate and vessel size) and hemorheology (blood hematocrit) affect the capacity for spheres to marginate (localize and adhere) to inflamed endothelium in a microfluidic model of human microvessels. Microspheres, particularly the 2 μm spheres, were found to show disproportionately higher margination than nanospheres in all hemodynamic conditions evaluated due to the poor ability of the latter to localize to the wall region from midstream. This work represents the first evidence that nanospheres may not exhibit "near wall excess" in microvessels, e.g., arterioles and venules, and therefore may not be suitable for imaging and drug delivery applications in cancer and other diseases affecting microvessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Form Follows Function: Nanoparticle Shape and Its Implications for Nanomedicine
Kinnear, C., Moore, T. L., Rodriguez-Lorenzo, L., Rothen-Rutishauser, B., & Petri-Fink, A. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00194 · Cited by 672
Extracellular vesicles as drug delivery systems: Lessons from the liposome field
van der Meel, R., Fens, M. H. A. M., Vader, P., van Solinge, W. W., Eniola-Adefeso, O., & Schiffelers, R. M. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.07.049 · Cited by 482
Self-citationVilla, C. H., Anselmo, A. C., Mitragotri, S., & Muzykantov, V. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.02.007 · Cited by 397
Organ-on-a-chip platforms for studying drug delivery systems
Bhise, N. S., Ribas, J., Manoharan, V., Zhang, Y. S., Polini, A., Massa, S., Dokmeci, M. R., & Khademhosseini, A. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.05.004 · Cited by 381
Microfluidic Devices: A Tool for Nanoparticle Synthesis and Performance Evaluation
Gimondi, S., Ferreira, H., Reis, R. L., & Neves, N. M. (2023) · ACS Nano · doi:10.1021/acsnano.3c01117 · Cited by 376
Metadata
- Authors
- Namdee, K., Thompson, A. J., Charoenphol, P., & Eniola-Adefeso, O.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-08
- Volume
- 29
- Issue
- 8
- Pages
- 2530-2535
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2315670676
- Cited by
- 137
- References
- 0
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Margination Propensity of Vascular-Targeted Spheres from Blood Flow in a Microfluidic Model of Human Microvessels. https://app.cochat.ai/papers/10.1021/la304746p
- The paper
- Namdee, K., Thompson, A. J., Charoenphol, P., & Eniola-Adefeso, O. (2013). Margination Propensity of Vascular-Targeted Spheres from Blood Flow in a Microfluidic Model of Human Microvessels. Langmuir. https://doi.org/10.1021/la304746p
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.