The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Glucose Biosensor Based on Nanocomposite Films of CdTe Quantum Dots and Glucose Oxidase
Abstract
A blood glucose sensor has been developed based on the multilayer films of CdTe semiconductor quantum dots (QDs) and glucose oxidase (GOD) by using the layer-by-layer assembly technique. When the composite films were contacted with glucose solution, the photoluminescence of QDs in the films was quickly quenched because the enzyme-catalyzed reaction product (H2O2) of GOD and glucose gave rise to the formation of surface defects on QDs. The quenching rate was a function of the concentration of glucose. The linear range and sensitivity for glucose determination could be adjusted by controlling the layers of QDs and GOD. The biosensor was used to successfully determine the concentration of blood glucose in real serum samples without sample pretreatment and exhibited satisfactory reproducibility and accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Cited by
Nanotechnologies in Food Science: Applications, Recent Trends, and Future Perspectives
Nile, S. H., Baskar, V., Selvaraj, D., Nile, A., Xiao, J., & Kai, G. (2020) · Nano-Micro Letters · doi:10.1007/s40820-020-0383-9 · Cited by 631
Biomolecule-stabilized Au nanoclusters as a fluorescence probe for sensitive detection of glucose
Jin, L., Shang, L., Guo, S., Fang, Y., Wen, D., Wang, L., Yin, J., & Dong, S. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.019 · Cited by 260
Metadata
- Authors
- Li, X., Zhou, Y., Zheng, Z., Yue, X., Dai, Z., Liu, S., & Tang, Z.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-04
- Volume
- 25
- Issue
- 11
- Pages
- 6580-6586
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2005649843
- Cited by
- 177
- References
- 3
- FWCI
- 17.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Glucose Biosensor Based on Nanocomposite Films of CdTe Quantum Dots and Glucose Oxidase. https://app.cochat.ai/papers/10.1021/la900066z
- The paper
- Li, X., Zhou, Y., Zheng, Z., Yue, X., Dai, Z., Liu, S., & Tang, Z. (2009). Glucose Biosensor Based on Nanocomposite Films of CdTe Quantum Dots and Glucose Oxidase. Langmuir. https://doi.org/10.1021/la900066z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.