Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 407

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Range of Applicability of the Wenzel and Cassie−Baxter Equations for Superhydrophobic Surfaces

Erbil, H. Yildirim, Cansoy, C. Elif·2009·Langmuir

Abstract

The Wenzel and Cassie-Baxter equations depending on the extent of liquid/solid interfacial contact area were generally used to estimate water contact angles on superhydrophobic surfaces. In this study, a simple method is proposed on the criterion to use the Wenzel and Cassie-Baxter equations to evaluate the contact angle results on superhydrophobic surfaces. In this method, the difference between the theoretical (geometric) and experimental contact angle-dependent Wenzel roughness parameter, Delta r(w), and Cassie-Baxter solid/liquid contact area fraction, Delta f(s)(CB) were determined, and the validity of these equations was evaluated. We used the data of eight recent publications where the water drop sits on square and cylindrical pillar structured superhydrophobic model surfaces. We evaluated the contact angle results of 166 patterned samples with our method. We also found that the effect of contact angle error margins was low to vary these parameters. In general, the use of the Wenzel equation was found to be wrong for most of the samples (74% of the samples for cylindrical and 58% for square pillar patterned surfaces), and the deviations from the theory were also high for the remaining (26% for cylindrical and 42% for square) samples, and it is concluded that the Wenzel equation cannot be used for superhydrophobic surfaces other than a few exceptions, especially for cylindrical patterns. For the Cassie-Baxter equation, two situations are possible: for positive Delta f(s)(CB), there is only a partial contact of the drop with the top solid surface, and, for negative Delta f(s)(CB), the penetration of the drop in between the pillars is possible, and thus the liquid drop is in contact with the lateral sides of the pillars. We found that 65% of the samples containing cylindrical pillars (52-77% with error margins) and 44% of the samples containing square pillars (38-50% with error margins) resulted in negative Delta f(s)(CB)(red) values. In addition, large deviations of experimental water contact angle results, theta r(e) from the theoretical theta r(CB) were also determined for most of the samples, indicating that the Cassie-Baxter equation should be applied to superhydrophobic surfaces with caution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la902098a

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 407

Metadata

Authors
Erbil, H. Y., & Cansoy, C. E.
Venue
Langmuir
Published
2009-07-27
Volume
25
Issue
24
Pages
14135-14145
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W1980183926
Cited by
407
References
2
FWCI
5.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Range of Applicability of the Wenzel and Cassie−Baxter Equations for Superhydrophobic Surfaces. https://app.cochat.ai/papers/10.1021/la902098a
The paper
Erbil, H. Y., & Cansoy, C. E. (2009). Range of Applicability of the Wenzel and Cassie−Baxter Equations for Superhydrophobic Surfaces. Langmuir. https://doi.org/10.1021/la902098a

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.