The damage caused to amphiphilic n -alkane monolayers under XPS measurement conditions was assessed in a combined XPS-FTIR study supplemented by additional AFM imaging and contact angle measurements. Nine different self-assembled monolayer/substrate systems were examined, comprising a long chain silane (C 18, OTS), a short chain silane (C 1, MTS), a functional (COOH-terminated) long chain silane (C 18, NTS ox ), a long chain carboxylic acid (C 20, AA), and four different solid substrates (silicon, quartz, glass, and ZnSe). Significant differences were observed in the behavior of the various examined monolayer systems under identical X-ray irradiation conditions. These are interpreted in terms of effects associated with the specific mode of layer-to-surface and intralayer coupling, the size of the monolayer hydrocarbon core, and the presence of radiation-sensitive functional groups in the layer. All these factors and their influence on the degradation path followed by a particular monolayer upon exposure to the X-rays were found to be interrelated, giving rise to a variety of possible damage patterns, including an unexpected overall stabilization effect initiated by the preferential rapid loss of a labile top functional group (NTS ox ). XPS is shown to be insufficient as a tool for the evaluation of the radiation-induced damage in such ultrathin films, because of its insensitivity to loss of hydrogen and to structural transformations that occur without a net loss of carbon from the surface. Independent methods of surface analysis (mainly FTIR), applied in conjunction with XPS, provide a more comprehensive picture of the induced damage, thus permitting a realistic interpretation of the XPS experimental data as well as the design of improved data acquisition procedures. This could also assist in the tailoring of monolayers with predetermined degradability, for specific purposes. Finally, results of combined AFM-XPS-FTIR-contact angle measurements suggest the possible formation of a “diamond-like” surface film upon extensive X-ray irradiation of an OTS/Si monolayer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oleic acid coating on the monodisperse magnetite nanoparticles
Zhang, L., He, R., & Gu, H.-C. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.05.023 · Cited by 994
Zharnikov, M., & Grunze, M. (2002) · Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena · doi:10.1116/1.1514665 · Cited by 262
Atomic modifications by synchrotron radiation at the calcite–ethanol interface
Pasarín, I. S., Bovet, N., Glyvradal, M., Nielsen, M. M., Bohr, J., Feidenhans'l, R., & Stipp, S. L. S. (2012) · Journal of Synchrotron Radiation · doi:10.1107/s0909049512021504 · Cited by 6
Metadata
- Authors
- Frydman, E., Cohen, H., Maoz, R., & Sagiv, J.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 13
- Issue
- 19
- Pages
- 5089-5106
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1965734176
- Cited by
- 171
- References
- 0
- FWCI
- 5.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monolayer Damage in XPS Measurements As Evaluated by Independent Methods. https://app.cochat.ai/papers/10.1021/la962058q
- The paper
- Frydman, E., Cohen, H., Maoz, R., & Sagiv, J. (1997). Monolayer Damage in XPS Measurements As Evaluated by Independent Methods. Langmuir. https://doi.org/10.1021/la962058q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.