Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 184

The DOI matches its Crossref record.

Gas Permeation and Diffusion in Cross-Linked Poly(ethylene glycol diacrylate)

Lin, Haiqing, Freeman, Benny D.·2006·Macromolecules

Abstract

The permeability of cross-linked poly(ethylene glycol diacrylate) (XLPEGDA) to He, H 2, O 2, N 2, CO 2, CH 4, C 2 H 4, C 2 H 6, C 3 H 6, and C 3 H 8 was determined at temperatures ranging from −20 to +45 °C and at fugacities up to approximately 15 atm for some gases. Diffusion coefficients of CO 2 and hydrocarbons were calculated as a function of temperature and local penetrant concentration. The effect of temperature and fugacity on permeability and diffusivity is satisfactorily described using either an activated diffusion model or a free volume-based model.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma051686o

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 184

Metadata

Authors
Lin, H., & Freeman, B. D.
Venue
Macromolecules
Published
2006-04-14
Volume
39
Issue
10
Pages
3568-3580
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W1992641283
Cited by
184
References
0
FWCI
19.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gas Permeation and Diffusion in Cross-Linked Poly(ethylene glycol diacrylate). https://app.cochat.ai/papers/10.1021/ma051686o
The paper
Lin, H., & Freeman, B. D. (2006). Gas Permeation and Diffusion in Cross-Linked Poly(ethylene glycol diacrylate). Macromolecules. https://doi.org/10.1021/ma051686o

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.