Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 162

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

On the Measurements of Rigidity Modulus of Soft Materials in Nanoindentation Experiments at Small Depth

Dokukin, Maxim E., Sokolov, Igor·2012·Macromolecules

Abstract

It is of interest to measure the modulus of rigidity at small indentation depths for many systems, such as thin films, nanocomposites, biomaterials, etc. Depth-dependence of the rigidity modulus of homogeneous soft materials is broadly observed in nanoindentation experiments. Typically, the modulus reaches its bulk value only when the indentation depth becomes relatively large. Nature of this effect (we suggest to call this “skin-effect” for short) is not well understood. It is not even clear if this is a real effect or an artifact. Here we present the results of precise indentation measurements based on the use of atomic force microscopy (AFM), which suggest that the skin-effect may be an artifact. It can be eliminated, and the bulk modulus can be measured at nanometer indentations if one (a) takes into account adhesion between the indenter and surface of interest, and (b) operates mostly within the linear stress–strain regime. To demonstrate it, we used three AFM probes of well-defined geometry (radii of the apex were 22, 810, and 1030 nm) to study the indentation of three different polymers of the bulk rigidity of 0.6–0.7 GPa (polyurethanes) and 2.8 GPa (polystyrene). The obtained force–indentation curves were processed through the Oliver–Pharr, Hertz, Johnson–Kendall–Roberts (JKR) and Derjaguin–Muller–Toporov (DMT) models. We found that the skin-effect disappeared when using dull (810 and 1030 nm) probes and processing the force-deformation data with either of the adhesion models (JKR or DMT). Moreover, the measured moduli were independent of the indentation depth. The values of the rigidity modulus were very close to the bulk values starting from the indentations of 2–3 nm. Such a small indentation seems to be the smallest one for soft materials at which the bulk modulus has been reached. When using the sharp (22 nm) probe, we were not able to reach the bulk moduli up to the maximum possible indentation allowed by the instrument 90 nm. The other sources of possible error in the modulus measurements are discussed. We conclude that the skin-effect originates mainly at both nonlinearity of stress–strain relation (occurs when using excessively sharp probes) and if the probe–surface adhesion is not taken into account (like in Oliver–Pharr and Hertz models).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ma202600b

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 162

Metadata

Authors
Dokukin, M. E., & Sokolov, I.
Venue
Macromolecules
Published
2012-05-11
Volume
45
Issue
10
Pages
4277-4288
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2327138964
Cited by
162
References
1
FWCI
14.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.