The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Temperature- and pH-Responsive Dense Copolymer Brushes Prepared by ATRP
Abstract
Dual responsive molecular brushes consisting of statistical copolymers of di(ethylene glycol) methyl ether methacrylate (MEO 2 MA) and either methacrylic acid (MAA) or N,N -dimethylaminoethyl methacrylate (DMAEMA) were synthesized by grafting from poly(2-(2-bromoisobutyroyloxy)ethyl methacrylate (PBIEM) macroinitiators using atom transfer radical polymerization (ATRP). Copolymer brushes with controlled composition and molecular weights ranging from M n = 600 000 to 1 400 000 with polydispersity indexes ( M w / M n ) between 1.18 and 1.45 were obtained. The lower critical solution temperature (LCST) of MEO 2 MA- stat -MAA decreased with the increasing molar fraction of MAA in the copolymer in deionized water but increased in buffer solution at pH 7. At pH 9, the hydrophilicity of polymer increased with ionization of carboxylic acid to further raise the LCST. On the other hand, the LCST of MEO 2 MA- stat- DMAEMA copolymers increased with increasing DMAEMA content at pH 4, 7, and 9. A bottle-brush terpolymer prepared from all three comonomers exhibited LCST at pH 4 and 7 but not at pH 9, which can be attributed to the stronger ionization of MAA. The responsive nature of the copolymer is enhanced by the densely graft structure of a brush copolymer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wang, J.-S., & Matyjaszewski, K. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00125a035 · Cited by 4,622
Self-citationPhysical stimuli-responsive polymeric micelles for anti-cancer drug delivery
Rapoport, N. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.009 · Cited by 1,002
pH-responsive hydrogels: Swelling model
Traitel, T., & Kost, J. (2004) · Advances in experimental medicine and biology · doi:10.1007/978-0-306-48584-8_3 · Cited by 22
Cited by
Stimuli-responsive molecular brushes
Lee, H.-I., Pietrasik, J., Sheiko, S. S., & Matyjaszewski, K. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.11.002 · Cited by 652
Self-citationAtrp in the design of functional materials for biomedical applications
Siegwart, D. J., Oh, J. K., & Matyjaszewski, K. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.08.001 · Cited by 613
Self-citationTemperature responsive bio-compatible polymers based on poly(ethylene oxide) and poly(2-oxazoline)s
Weber, C., Hoogenboom, R., & Schubert, U. S. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.10.002 · Cited by 533
Boyer, C., Corrigan, N. A., Jung, K., Nguyen, D., Nguyen, T.-K., Adnan, N. N. M., Oliver, S., Shanmugam, S., & Yeow, J. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00396 · Cited by 483
Bottlebrush polymers: From controlled synthesis, self-assembly, properties to applications
Li, Z., Tang, M., Liang, S., Zhang, M., Biesold, G. M., He, Y., Hao, S.-M., Choi, W., Liu, Y., Peng, J., et al. (2021) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2021.101387 · Cited by 318
Metadata
- Authors
- Yamamoto, S.-I., Pietrasik, J., & Matyjaszewski, K.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-09-04
- Volume
- 41
- Issue
- 19
- Pages
- 7013-7020
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2091148704
- Cited by
- 177
- References
- 3
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.