The DOI matches its Crossref record.
Poly(ethylene oxide) Grafted to Silicon Surfaces: Grafting Density and Protein Adsorption
Abstract
Poly(ethylene oxide) (PEO) polymer, in linear and star form, was covalently grafted to silicon surfaces, and the surfaces were tested for their ability to adsorb proteins. Linear PEG of molecular weight 3400, 10 000, and 20 000 g/mol and star PEO molecules were coupled via their terminal hydroxyl groups activated by tresyl chloride to aminosilane-treated silicon wafers. The amount of PEO coupled to the surface was varied by changing the concentration of the tresyl-PEO solution. The dry PEO thickness on the surface was measured using X-ray photoelectron spectroscopy (XPS) and ellipsometry, from which the grafting density was calculated. The PEO surfaces were exposed to solutions of each of three proteins: cytochrome-c, albumin, and fibronectin. The degree of adsorption of each protein was determined by XPS and ellipsometry and recorded as a function of PEO grafting density. All three proteins were found to reach zero adsorption at the highest grafting densities on all three PEG surfaces, which for all three PEG surfaces was a PEO content of 100 +/- 10 ng/cm2. On both star PEO surfaces, albumin and fibronectin decreased to zero adsorption at intermediate values of grafting density, whereas cytochrome-c continued to adsorb at all grafting densities, although with a decreasing trend. A physical model of the surface helped explain these protein adsorption results in terms of the spacing and degree of overlap of grafted PEO chains.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Barbey, R., Lavanant, L., Paripovic, D., Schüwer, N., Sugnaux, C., Tugulu, S., & Klok, H.-A. (2009) · Chemical Reviews · doi:10.1021/cr900045a · Cited by 1,753
Ge, Z., & Liu, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60048c · Cited by 914
Functionalized silk-based biomaterials for bone formation
Sofia, S., McCarthy, M. B., Gronowicz, G., & Kaplan, D. L. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200101)54:1<139::aid-jbm17>3.0.co;2-7 · Cited by 819
Self-citationProtein Resistance of Titanium Oxide Surfaces Modified by Biologically Inspired mPEG−DOPA
Dalsin, J. L., Lin, L., Tosatti, S., Vörös, J., Textor, M., & Messersmith, P. B. (2005) · Langmuir · doi:10.1021/la048626g · Cited by 455
Proteins, platelets, and blood coagulation at biomaterial interfaces
Xu, L.-C., Bauer, J. W., & Siedlecki, C. A. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.09.040 · Cited by 391
Metadata
- Authors
- Sofia, S. J., Premnath, V., & Merrill, E. W.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 1998-07-01
- Volume
- 31
- Issue
- 15
- Pages
- 5059-5070
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2051489942
- Cited by
- 610
- References
- 0
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Poly(ethylene oxide) Grafted to Silicon Surfaces: Grafting Density and Protein Adsorption. https://app.cochat.ai/papers/10.1021/ma971016l
- The paper
- Sofia, S. J., Premnath, V., & Merrill, E. W. (1998). Poly(ethylene oxide) Grafted to Silicon Surfaces: Grafting Density and Protein Adsorption. Macromolecules. https://doi.org/10.1021/ma971016l
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.