The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Local Refractive Index Dependence of Plasmon Resonance Spectra from Individual Nanoparticles
Abstract
We present an experimental optical darkfield microscope study of the dependence of the plasmon resonance spectrum of individual silver nanoparticles on the local index of refraction. We systematically characterize the position of the resonance peaks associated with the same set of individual silver nanoparticles embedded sequentially in index oils with increasing refractive index. This technique effectively allows the local refractive index to be stepped in increments of 0.04. As the local index is increased, the spectrum from each of the nanoparticles generally undergoes a very regular and reproducible red shift; however, we find that the amount of red shift per index increase varies depending on the shape of the nanoparticle and the mode of excitation. In particular, we find that the spectral peak that occurs in triangular nanoparticles exhibits a noticeably larger red shift than that associated with the dipole mode corresponding to spherical nanoparticles. Our results are consistent with experiments performed on ensembles of similar nanoparticles and suggest that individual nanoparticles may be utilized in biosensing applications where currently ensembles are being investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Cited by
Plasmonics: Localization and guiding of electromagnetic energy in metal/dielectric structures
Maier, S. A., & Atwater, H. A. (2005) · Journal of Applied Physics · doi:10.1063/1.1951057 · Cited by 1,923
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Nanofabricated media with negative permeability at visible frequencies
Grigorenko, A. N., Geim, A. K., Gleeson, H. F., Zhang, Y., Firsov, A. A., Khrushchev, I. Y., & Petrovic, J. (2005) · Nature · doi:10.1038/nature04242 · Cited by 616
Biomedical Applications of Plasmon Resonant Metal Nanoparticles
Liao, H., Nehl, C. L., & Hafner, J. H. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.201 · Cited by 396
Optical properties of metallic nanoparticles: manipulating light, heat and forces at the nanoscale
Coronado, E. A., Encina, E. R., & Stefani, F. D. (2011) · Nanoscale · doi:10.1039/c1nr10788g · Cited by 284
Metadata
- Authors
- Mock, J. J., Smith, D. R., & Schultz, S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-03-14
- Volume
- 3
- Issue
- 4
- Pages
- 485-491
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2145538244
- Cited by
- 839
- References
- 2
- FWCI
- 12.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.