The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Water-Soluble Poly(acrylic acid) Grafted Luminescent Silicon Nanoparticles and Their Use as Fluorescent Biological Staining Labels
Abstract
UV-induced graft polymerization of acrylic acid (AAc) on the surface of silicon nanoparticles was used to prepare a stable aqueous luminescent silicon nanoparticle solution. By grafting a water-soluble polymer on the particle surface, the dispersions in water of the silicon nanoparticles became very stable and clear aqueous solutions could be obtained. XPS and NMR spectroscopy confirmed that PAAc was covalently grafted to the silicon nanoparticles. The grafted PAAc on silicon particles increased not only the dispersibility but also improved the photoluminescence stability of the silicon nanoparticles against degradation by water. The surface-modified nanoparticles were used as biological labels for cell imaging. The Si quantum dot labels exihibited bright fluorescence images and provided higher resistance to photobleaching than the commonly used organic dyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Nanocrystals as Fluorescent Biological Labels
Bruchez, M., Moronne, M., Gin, P., Weiss, S., & Alivisatos, A. P. (1998) · Science · doi:10.1126/science.281.5385.2013 · Cited by 8,613
Silicon quantum wire array fabrication by electrochemical and chemical dissolution of wafers
Canham, L. T. (1990) · Applied Physics Letters · doi:10.1063/1.103561 · Cited by 7,997
Theoretical aspects of the luminescence of porous silicon
Delerue, C., Allan, G., & Lannoo, M. (1993) · Physical Review B · doi:10.1103/physrevb.48.11024 · Cited by 995
A Liquid-Solution-Phase Synthesis of Crystalline Silicon
Heath, J. R. (1992) · Science · doi:10.1126/science.258.5085.1131 · Cited by 287
Hamilton, B. (1995) · Semiconductor Science and Technology · doi:10.1088/0268-1242/10/9/001 · Cited by 167
Detection of Nitric Oxide and Nitrogen Dioxide with Photoluminescent Porous Silicon
Harper, J., & Sailor, M. J. (1996) · Analytical Chemistry · doi:10.1021/ac960642y · Cited by 115
Structured films of light-emitting silicon nanoparticles produced by cluster beam deposition
Huisken, F., Kohn, B., & Paillard, V. (1999) · Applied Physics Letters · doi:10.1063/1.124176 · Cited by 61
Cited by
Biodegradable luminescent porous silicon nanoparticles for in vivo applications
Park, J.-H., Gu, L., von Maltzahn, G., Ruoslahti, E., Bhatia, S. N., & Sailor, M. J. (2009) · Nature Materials · doi:10.1038/nmat2398 · Cited by 1,897
Nonthermal Plasma Synthesis of Nanocrystals: Fundamental Principles, Materials, and Applications
Kortshagen, U. R., Sankaran, R. M., Pereira, R. N., Girshick, S. L., Wu, J. J., & Aydil, E. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00039 · Cited by 437
Cheng, X., Lowe, S. B., Reece, P. J., & Gooding, J. J. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60353a · Cited by 406
Imaging of zinc oxide nanoparticle penetration in human skin in vitro and in vivo
Zvyagin, A. V., Zhao, X., Gierden, A., Sanchez, W., Ross, J. A., & Roberts, M. S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041492 · Cited by 317
Group IV Nanoparticles: Synthesis, Properties, and Biological Applications
Fan, J., & Chu, P. K. (2010) · Small · doi:10.1002/smll.201000543 · Cited by 288
Metadata
- Authors
- Li, Z. F., & Ruckenstein, E.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-06-18
- Volume
- 4
- Issue
- 8
- Pages
- 1463-1467
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2050539207
- Cited by
- 417
- References
- 7
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.