The DOI matches its Crossref record.
Carbon Nanotubes Loaded with Magnetic Particles
Abstract
We describe a simple and versatile technique to produce magnetic tubes by filling carbon nanotubes (CNTs) with paramagnetic iron oxide particles ( approximately 10 nm diameter). Commercial ferrofluids were used to fill CNTs with an average outer diameter of 300 nm made via chemical vapor deposition into alumina membranes. Transmission electron microscopy study shows a high density of particles inside the CNT. Experiments using external magnetic fields demonstrate that almost 100% of the nanotubes become magnetic and can be easily manipulated in magnetic field. These one-dimensional magnetic nanostructures can find numerous applications in nanotechnology, memory devices, optical transducers for wearable electronics, and in medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetically Separable Nanocatalysts: Bridges between Homogeneous and Heterogeneous Catalysis
Shylesh, S., Schünemann, V., & Thiel, W. R. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905684 · Cited by 1,428
Carbon Nanotubes: A Review on Structure and Their Interaction with Proteins
Saifuddin, N., Raziah, A. Z., & Junizah, A. R. (2013) · Journal of Chemistry · doi:10.1155/2013/676815 · Cited by 683
Progressive utilisation prospects of coal fly ash: A review
Gollakota, A. R. K., Volli, V., & Shu, C.-M. (2019) · Science of The Total Environment · doi:10.1016/j.scitotenv.2019.03.337 · Cited by 548
Magnetic solid-phase extraction using carbon nanotubes as sorbents: a review
Herrero-Latorre, C., Barciela-García, J., García-Martín, S., Peña-Crecente, R. M., & Otárola-Jiménez, J. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.07.046 · Cited by 344
Qing, Y., Min, D., Zhou, Y., Luo, F., & Zhou, W. (2015) · Carbon · doi:10.1016/j.carbon.2015.01.002 · Cited by 310
Xu, X., Li, H., Zhang, Q., Hu, H., Zhao, Z., Li, J., Li, J., Qiao, Y., & Gogotsi, Y. (2015) · ACS Nano · doi:10.1021/nn507426u · Cited by 282
Self-citationMultifunctional carbon-nanotube cellular endoscopes.
Singhal, R., Orynbayeva, Z., Kalyana Sundaram, R. V., Niu, J. J., Bhattacharyya, S., Vitol, E. A., Schrlau, M. G., Papazoglou, E. S., Friedman, G., & Gogotsi, Y. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.241 · Cited by 241
Self-citationThe use of magnetic nanoparticles in cancer theranostics: Toward handheld diagnostic devices
Hajba, L., & Guttman, A. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.02.001 · Cited by 111
Magnetic (nano)materials as an useful tool for sample preparation in analytical methods. A review
Ríos, A., Zougagh, M., & Bouri, M. (2013) · Analytical Methods · doi:10.1039/c3ay40306h · Cited by 108
Molecular Cargo Delivery Using Multicellular Magnetic Microswimmers
Yan, X., Xu, J., Zhou, Q., Jin, D., Vong, C. I., Feng, Q., Ng, D. H. L., Bian, L., & Zhang, L. (2019) · Applied Materials Today · doi:10.1016/j.apmt.2019.02.006 · Cited by 94
Metadata
- Authors
- Korneva, G., Ye, H., Gogotsi, Y., Halverson, D., Friedman, G., Bradley, J.-C., & Kornev, K. G.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2005-03-30
- Volume
- 5
- Issue
- 5
- Pages
- 879-884
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1973626287
- Cited by
- 423
- References
- 0
- FWCI
- 12.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.