The DOI matches its Crossref record.
Volatile Organic Compound Detection Using Nanostructured Copolymers
Abstract
Regioregular polythiophene-based conductive copolymers with highly crystalline nanostructures are shown to hold considerable promise as the active layer in volatile organic compound (VOC) chemresistor sensors. While the regioregular polythiophene polymer chain provides a charge conduction path, its chemical sensing selectivity and sensitivity can be altered either by incorporating a second polymer to form a block copolymer or by making a random copolymer of polythiophene with different alkyl side chains. The copolymers were exposed to a variety of VOC vapors, and the electrical conductivity of these copolymers increased or decreased depending upon the polymer composition and the specific analytes. Measurements were made at room temperature, and the responses were found to be fast and appeared to be completely reversible. Using various copolymers of polythiophene in a sensor array can provide much better discrimination to various analytes than existing solid state sensors. Our data strongly indicate that several sensing mechanisms are at play simultaneously, and we briefly discuss some of them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
A review study of (bio)sensor systems based on conducting polymers
Ates, M. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.01.035 · Cited by 431
Review of nanomaterials as sorbents in solid-phase extraction for environmental samples
Azzouz, A., Kailasa, S. K., Lee, S. S., J. Rascón, A., Ballesteros, E., Zhang, M., & Kim, K.-H. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.009 · Cited by 319
Prospects and Challenges of Volatile Organic Compound Sensors in Human Healthcare
Jalal, A. H., Alam, F., Roychoudhury, S., Umasankar, Y., Pala, N., & Bhansali, S. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00400 · Cited by 315
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Metadata
- Authors
- Li, B., Sauvé, G., Iovu, M. C., Jeffries-EL, M., Zhang, R., Cooper, J., Santhanam, S., Schultz, L., Revelli, J. C., Kusne, A. G., Kowalewski, T., Snyder, J. L., Weiss, L. E., Fedder, G. K., McCullough, R. D., & Lambeth, D. N.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-14
- Volume
- 6
- Issue
- 8
- Pages
- 1598-1602
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1966795693
- Cited by
- 213
- References
- 0
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volatile Organic Compound Detection Using Nanostructured Copolymers. https://app.cochat.ai/papers/10.1021/nl060498o
- The paper
- Li, B., Sauvé, G., Iovu, M. C., Jeffries-EL, M., Zhang, R., Cooper, J., Santhanam, S., Schultz, L., Revelli, J. C., Kusne, A. G., Kowalewski, T., Snyder, J. L., Weiss, L. E., Fedder, G. K., McCullough, R. D., & Lambeth, D. N. (2006). Volatile Organic Compound Detection Using Nanostructured Copolymers. Nano Letters. https://doi.org/10.1021/nl060498o
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.