Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

Magnetite-Loaded Carrier Erythrocytes as Contrast Agents for Magnetic Resonance Imaging

Brähler, M., Georgieva, R., Buske, N., Müller, A., Müller, S., Pinkernelle, J., Teichgräber, U., Voigt, A., Bäumler, H.·2006·Nano Letters

Abstract

Superparamagnetic iron oxide nanoparticles (SPIONs) are commonly used in magnetic resonance imaging (MRI), but their fast phagocytosis makes them less than ideal for this application. To circumvent the lymphocyte-macrophage system, we encapsulated SPIONs into red blood cells (RBCs). For loading, the RBC's membrane was opened by swelling under hypoosmotic conditions and subsequently resealed. In this work, we demonstrate that SPIONs can be loaded into RBCs in a concentration sufficient to obtain strong contrast enhancement in MRI.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nl0618501

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Brähler, M., Georgieva, R., Buske, N., Müller, A., Müller, S., Pinkernelle, J., Teichgräber, U., Voigt, A., & Bäumler, H.
Venue
Nano Letters
Published
2006-10-19
Volume
6
Issue
11
Pages
2505-2509
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2044582876
Cited by
183
References
0
FWCI
6.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetite-Loaded Carrier Erythrocytes as Contrast Agents for Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1021/nl0618501
The paper
Brähler, M., Georgieva, R., Buske, N., Müller, A., Müller, S., Pinkernelle, J., Teichgräber, U., Voigt, A., & Bäumler, H. (2006). Magnetite-Loaded Carrier Erythrocytes as Contrast Agents for Magnetic Resonance Imaging. Nano Letters. https://doi.org/10.1021/nl0618501

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.