The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Metal-Enhanced Single-Molecule Fluorescence on Silver Particle Monomer and Dimer: Coupling Effect between Metal Particles
Open accessAbstract
We prepared silver particle dimers with single Cy5 molecules localized between coupled metal particles. The silver particles with a 20 nm diameter were chemically bound with single-stranded oligonucleotides. The dimers were formed by hybridization with double-length single-stranded oligonucleotides that contained single Cy5 molecules. The image analysis revealed that the single-molecule fluorescence was enhanced 7-fold on the metal monomer and 13-fold on the metal dimer relative to the free Cy5-labeled oligonucleotide in the absence of metal. The lifetimes were shortened on the silver monomers and further shortened on the silver dimers, demonstrating the near-field interaction mechanism of fluorophore with the metal substrate. Finite-difference time-domain (FDTD) calculations were employed to study the distribution of electric field near the metal monomer and dimer. The coupling effect of metal particle on the fluorescence enhancement was discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cited by
Guerrini, L., & Graham, D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35118h · Cited by 441
Schietinger, S., Barth, M., Aichele, T., & Benson, O. (2009) · Nano Letters · doi:10.1021/nl900384c · Cited by 398
Lee, J.-S., Shevchenko, E. V., & Talapin, D. V. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802890f · Cited by 349
Metadata
- Authors
- Zhang, J., Fu, Y., Chowdhury, M. H., & Lakowicz, J. R.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-06-20
- Volume
- 7
- Issue
- 7
- Pages
- 2101-2107
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1998329957
- Cited by
- 387
- References
- 1
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.