The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Enhanced Cellular Mobility Guided by TiO2 Nanotube Surfaces
Abstract
The in vitro endothelial response of primary bovine aortic endothelial cells (BAECs) was investigated on a flat Ti surface vs a nanostructured TiO2 nanotube surface. The nanotopography provided nanoscale cues that facilitated cellular probing, cell sensing, and especially cell migration, where more organized actin cytoskeletal filaments formed lamellipodia and locomotive morphologies. Motile cell protrusions were able to probe down into the nanotube pores for contact stimulation, and focal adhesions were formed and disassembled readily for enhanced advancement of cellular fronts, which was not observed on a flat substrate of titanium. NOx and endothelin-1 functional assays confirmed that the nanotubes also up-regulated an antithrombic cellular state for maintaining vascular tone. The enhanced endothelial response to TiO2 nanotubes is significant for a potential modification of vascular stent surfaces in order to increase the rate and reliability of endothelialization and endothelial cell migration onto the stent for repairing arterial injury after activation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Pathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
Finn, A. V., Joner, M., Nakazawa, G., Kolodgie, F., Newell, J., John, M. C., Gold, H. K., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.107.693739 · Cited by 1,277
Nanosize and Vitality: TiO2 Nanotube Diameter Directs Cell Fate
Park, J., Bauer, S., von der Mark, K., & Schmuki, P. (2007) · Nano Letters · doi:10.1021/nl070678d · Cited by 1,193
Activation of Integrin Function by Nanopatterned Adhesive Interfaces
Arnold, M., Cavalcanti‐Adam, E. A., Glass, R., Blümmel, J., Eck, W., Kantlehner, M., Kessler, H., & Spatz, J. P. (2004) · ChemPhysChem · doi:10.1002/cphc.200301014 · Cited by 1,164
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Michiels, C. (2003) · Journal of Cellular Physiology · doi:10.1002/jcp.10333 · Cited by 773
Influence of engineered titania nanotubular surfaces on bone cells
Popat, K. C., Leoni, L., Grimes, C. A., & Desai, T. A. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.03.020 · Cited by 598
Cells in focus: endothelial cell
Sumpio, B. E., Timothy Riley, J., & Dardik, A. (2002) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/s1357-2725(02)00075-4 · Cited by 531
Significantly accelerated osteoblast cell growth on aligned TiO2 nanotubes
Oh, S., Daraio, C., Chen, L., Pisanic, T. R., Fiñones, R. R., & Jin, S. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30722 · Cited by 474
Self-citationIn vitro reaction of endothelial cells to polymer demixed nanotopography
Dalby, M. J., Riehle, M. O., Johnstone, H., Affrossman, S., & Curtis, A. S. G. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00424-0 · Cited by 461
Unanswered Questions — Drug-Eluting Stents and the Risk of Late Thrombosis
Maisel, W. H. (2007) · New England Journal of Medicine · doi:10.1056/nejmp068305 · Cited by 268
Zhu, X., Chen, J., Scheideler, L., Altebaeumer, T., Geis-Gerstorfer, J., & Kern, D. (2004) · Cells Tissues Organs · doi:10.1159/000081089 · Cited by 161
Interaction of animal cells with ordered nanotopography
Gallagher, J. O., McGhee, K. F., Wilkinson, C. D. W., & Riehle, M. O. (2002) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2002.806918 · Cited by 140
Self-citationInfluence of Surface Topography on Endothelialization of Intravascular Metallic Material
Palmaz, J. C., Benson, A. E., & Sprague, E. A. (1999) · Journal of Vascular and Interventional Radiology · doi:10.1016/s1051-0443(99)70063-1 · Cited by 119
Cell Signaling Arising From Nanotopography: Implications for Nanomedical Devices
Curtis, A. S. G., Dalby, M. J., & Gadegaard, N. (2006) · Nanomedicine · doi:10.2217/17435889.1.1.67 · Cited by 113
Normal endothelial cell function
Pearson, J. D. (2000) · Lupus · doi:10.1191/096120300678828299 · Cited by 111
Bianchi, F., Vassalle, C., Simonetti, M., Vozzi, G., Domenici, C., & Ahluwalia, A. D. (2005) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856206774879117 · Cited by 21
Cited by
Alternative Antimicrobial Approach: Nano-Antimicrobial Materials
Beyth, N., Houri-Haddad, Y., Domb, A., Khan, W., & Hazan, R. (2015) · Evidence-Based Complementary and Alternative Medicine · doi:10.1155/2015/246012 · Cited by 837
Improved bone-forming functionality on diameter-controlled TiO2 nanotube surface
Brammer, K. S., Oh, S., Cobb, C. J., Bjursten, L. M., Heyde, H. V. D., & Jin, S. (2009) · Acta Biomaterialia · doi:10.1016/j.actbio.2009.05.008 · Cited by 593
Self-citationZhao, L., Mei, S., Chu, P. K., Zhang, Y., & Wu, Z. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.014 · Cited by 465
Bacterial Retention on Superhydrophobic Titanium Surfaces Fabricated by Femtosecond Laser Ablation
Fadeeva, E., Truong, V. K., Stiesch, M., Chichkov, B. N., Crawford, R. J., Wang, J., & Ivanova, E. P. (2011) · Langmuir · doi:10.1021/la104607g · Cited by 440
Titanium dioxide nanotubes enhance bone bonding in vivo
Bjursten, L. M., Rasmusson, L., Oh, S., Smith, G. C., Brammer, K. S., & Jin, S. (2010) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32463 · Cited by 356
Self-citation
Metadata
- Authors
- Brammer, K. S., Oh, S., Gallagher, J. O., & Jin, S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-02-06
- Volume
- 8
- Issue
- 3
- Pages
- 786-793
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2005834846
- Cited by
- 271
- References
- 18
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.