Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Abstract
Field effect transistors (FETs) are widely used for the label-free detection of analytes in chemical and biological experiments. Here we demonstrate that the apparent sensitivity of a dual-gated silicon nanowire FET to pH can go beyond the Nernst limit of 60 mV/pH at room temperature. This result can be explained by a simple capacitance model including all gates. The consistent and reproducible results build to a great extent on the hysteresis- and leakage-free operation. The dual-gate approach can be used to enhance small signals that are typical for bio- and chemical sensing at the nanoscale.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The DG ISFET platform effectively breaks through the barrier of Nernst response, showing outstanding sensitivity ranging from 220 mV/pH to 2.25 V/pH.
“In literature, the platform effectively breaks through the barrier of Nernst response, showing outstanding sensitivity ranging from 220 mV/pH to 2.25 V/pH1314.”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [13]
The ISFETs with an additional gate, called the DG ISFET, have been first proposed utilizing organic thin-film transistor (TFT) and silicon nanowire field-effect transistor in order to beat the Nernst response.
“In the meantime, the ISFETs with an additional gate, called as the DG ISFET, have been first proposed, utilizing organic thin-film transistor (TFT)12 and silicon nanowire field-effect transistor13, in order to beat the Nernst response”
From Performance Enhancement of Capacitive-Coupling Dual-gate Ion-Sensitive Field-Effect Transistor in Ultra-Thin-Body (2014) · cites this paper as [13]
The EFN-enhanced sensitivity is not due to additional biasing as argued for the dual-gated SiNW.
“It should be noted that the EFN-enhanced sensitivity is not due to additional biasing as was argued for the dual-gated SiNW.35”
From Specific and label-free femtomolar biomarker detection with an electrostatically formed nanowire biosensor (2013) · cites this paper as [35]
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224 · see citing works
Jang, H.-J., & Cho, W.-J. (2014) · Scientific Reports · doi:10.1038/srep05284 · Cited by 103 · see citing works
Shalev, G., Landman, G., Amit, I., Rosenwaks, Y., & Levy, I. (2013) · NPG Asia Materials · doi:10.1038/am.2012.75 · Cited by 61 · see citing works
- Authors
- Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C.
- Affiliations
- University of Basel (CH)
- Department of Physics, University of Basel, Klingelbergstrasse 82, CH-4056 Basel, Switzerland
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-25
- Volume
- 10
- Issue
- 6
- Pages
- 2268-2274
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1967539302
- Cited by
- 353
- References
- 1
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 16 · 2023: 14 · 2022: 17 · 2021: 26 · 2020: 27 · 2019: 25 · 2018: 23 · 2017: 27 · 2016: 27 · 2015: 22 · 2014: 34 · 2013: 32 · 2012: 22
- FWCI
- 14.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Nano Letters (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Nanowire Synthesis and Applications
- Physical Sciences › Chemical Engineering › Bioengineering › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advancements in Semiconductor Devices and Circuit Design
- Keywords
- silicon nanowire transistors, pH sensing, label-free detection, capacitance model, signal amplification, hysteresis-free operation, chemical and biological sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review